Showing 431 items
matching anaesthetic
-
Geoffrey Kaye Museum of Anaesthetic History
Mask, Schimmelbusch, Elliott, c. 1930s
Curt Theodor Schimmelbusch (November 16, 1860 – August 2, 1895) was a German physician and pathologist who invented the Schimmelbusch mask, for the safe delivery of anaesthetics to surgical patients. In 1890, Schimmelbusch invented a mask for the delivery of anaesthetics to surgical patients. It was primarily designed for ether anaesthesia, but he also proposed its use for chloroform anaesthesia. Schimmelbusch designed a metal mask, over which a gauze could be stretched and secured. The mask was placed over the patient's mouth and nose, and anaesthetic was applied to the gauze, allowing the patient to inhale the anaesthetic as they breathed normally. Around the edge of the mask, a trough collected the residual anaesthetic, rather than allowing it to drip onto the patient's face.Oval shaped metal mask with a collapsible cross-shaped dome, hinged clamp and flat handleStamped into underside of handle: ELLIOTT SYDNEYschimmelbusch, mask, open method, chloroform, ether, german, physician, pathologist -
Geoffrey Kaye Museum of Anaesthetic History
Photograph, c1940s
Possibly part of a series of photographs taken at the Geoffrey Kaye Museum when it was located at the University of Melbourne in the late 1940s, photographer unknown. The photograph was reproduced in the book One Grand Chain : The History of Anaesthesia in Australia 1846 - 1962 : Volume 2 1934 - 1962, Gwen Wilson, edited by Jeanette Thirlwell Jones, on page 459.Black and white photography depicting a group of six male students rehearsing with anaesthetic apparatus. Five of the students are standing and one student on the left of the photograph is sitting and holding an inhaler to his face. There are two apparatus displayed.•Handwritten in grey pencil on reverse: Frame 17 •Handwritten in blue ink on reverse: sample. •Handwritten in grey pencil on reverse: 2 [in a circle] •Handwritten in grey pencil on reverse: 15 [in a circle, with the 5 crossed out] •Label which was originally glued to bottom on photograph which has since detached, written in all capitals with white ink on black paper: Students rehearsing with current apparatus, displayed in functional order and in sectionstudents, training session, anaesthetic machine -
Geoffrey Kaye Museum of Anaesthetic History
Ampoules, Procaine, Elliotts & Australian Drug Pty. Ltd
Provocaine hydrochloride is a local anaesthetic.Two blue cardboard boxes containing six (6) ampoules of procaine hydrochloride. One box has been opened but the six ampoules remain intact. The other box has unbroken adhesive seals. The ampoules have been separated by cardboard barriers which are lined with shredded paper for absorbency. There is a corrugated carboard layer between the lid and the ampoules as well. The instructions printed in the lid of the box mention a file for opening the ampoules but that is missing.provocaine hydrochloride, local anaesthetic, novocain, novocaine, adrenaline, elliotts & australian drugs pty ltd, sydney -
Royal Australian and New Zealand College of Obstetricians & Gynaecologists (RANZCOG)
Equipment - 20ml Astra Marcain 0.25% theatre pack associated with Dr Lachlan Hardy-Wilson
Bupivacaine is used as a local anaesthetic. It is given as an epidural injection into the spinal column to produce numbness during labour, surgery, and for certain other medical procedures. It is also sometimes used as an anaesthetic for dental procedures.This is one of a collection of items received from the practice of Dr Lachlan Hardy-Wilson, FRCOG, Launceston, Tasmania.Bottle of medication in sterile packaging. The bottle is 20ml and contains bupivacaine hydrochloride. Label on packaging reads 'STERILE THEATRE PACK/20ml MarcainTM 0.25%/BUPIVACAINE HCI/Store below 25C'.surgery -
Geoffrey Kaye Museum of Anaesthetic History
Equipment - Fluothane (Halothane)
Prior to the introduction of halothane, most anaesthetic agents were flammable or had other limitations such as nausea, arrhythmias or slow recovery. It was clear there was a need for a new, non-flammable anaesthetic agent. Fluothane is a brand name for halothane.Amber glass bottle with white rounded manufacturer's label and green printed text, with white metal screw top lid. The bottle is housed in its original cardboard packaging. Bottle has been decanted.halothane, fluothane, non-flammable, nausea, fluorinated -
Geoffrey Kaye Museum of Anaesthetic History
Book, Catalogue, Allen & Hanburys, Surgical Instruments and Appliances. Operation Tables, Sterilizers and Hospital Equipment. Sterilized Surgical Dressings, Sutures and Ligatures, 1938
Surgical and anaesthetic equipment catalogue from 1938Black bound book with gold leaf text on front cover and spine and white internal pages with blue printed text and illustrationsBook plate adhered to inside cover: SCIENTIA SAULTEM FERAMUS / SIR ANTHONY JEPHCOTT, BT. Handwritten in blue ink: J. Jephcott / NOV 1977 -
J. Ward Museum Complex
Equipment - Medical Equipment, Chloroform Mask
Chloroform mask, stainless steel, without gauze cover. British Made.#surgicalequipment, #chloroformmask, anaesthetic -
Ballarat Base Hospital Trained Nurses League
Anaesthetic Mask - Schimmelbusch
anaesthetic, mask, schimmelbusch -
Ballarat Base Hospital Trained Nurses League
Anaesthetic Mask - Schimmelbusch
anaesthetic, mask, schimmelbusch -
Geoffrey Kaye Museum of Anaesthetic History
Photograph
The Lidwill machine was designed by Mark Lidwill in 1913, for the purpose of mechanical or insufflation anaesthesia. It was manufactured by Elliott Bros. of Sydney.Colour photograph of a Lidwill anaesthetic machine sitting on carpet. A circular metal ether vaporiser sits on a brown wooden base, with brown tubes connecting to a trap bottle and metal valves, and a brown tube connected to the valve is coiled on the floor.anaesthetic equipment, lidwill anaesthetic machine, mark lidwill, ether vaporiser, elliott bros sydney -
Alfred Hospital Nurses League - Nursing Archive
Document - Lecture Notes - Alfred Hospital, anaesthetics lecture notes for nurses (Alfred Hospital medical lectures), [ca 1980]
Alfred Hospital Medical Nursing lecture notes [ca. 1973-1976] - belonged to Susan Kim Hollands (2/73). Kim has been an AHNL member for many years, is now an archive volunteer. Her career was at the Alfred until 1980, during which time she completed nursing training, staffing and a renal-respiratory intensive care course.buff coloured manilla folder containing typed notes, purple stamp on front cover with staple marks from removed staples, handwritten annotationsnon-fictionAlfred Hospital Medical Nursing lecture notes [ca. 1973-1976] - belonged to Susan Kim Hollands (2/73). Kim has been an AHNL member for many years, is now an archive volunteer. Her career was at the Alfred until 1980, during which time she completed nursing training, staffing and a renal-respiratory intensive care course. nurse lecture notes from 1970s, alfred hospital, nursing training, anaesthetics -
Geoffrey Kaye Museum of Anaesthetic History
Bottle, chloroform
Chloroform was a popular anaesthetic agent in the early years of medical anaesthesia. Brown glass bottle with smooth face and vertical ridged reverse. The front has a white manufacturer's label with another smaller label on the reverse. There is sealing wax over the lid. There is also a brown cardboard box and lid for storing the bottle. Moulded into side of cardboard box: BUSH Moulded into top of cardboard box: W.J. BUSH / & CO. LTD / LONDON E8 [partially obscured by manufacturer's label stuck over top]chloroform, anaesthesia, w.j bush & co. limited, london -
Geoffrey Kaye Museum of Anaesthetic History
Equipment - Cylinder, Nitrous Oxide
Nitrous oxide has been used for anaesthesia in dentistry since December 1844, where Horace Wells made the first 12–15 dental operations with the gas in Hartford. Its debut as a generally accepted method, however, came in 1863, when Gardner Quincy Colton introduced it more broadly at all the Colton Dental Association clinics, that he founded in New Haven and New York City. Hospitals administer nitrous oxide as one of the anaesthetic drugs delivered by anaesthetic machines. Nitrous oxide is a weak general anaesthetic, and so is generally not used alone in general anaesthesia. In general anaesthesia it is used as a carrier gas with oxygen for more powerful general anaesthetic drugs.Medium size empty blue coloured cylinder with rounded base and painted white neck once containing Nitrous Oxide. A large blue on white diamond shaped label is adhered onto the main cylinder body.Printed on manufacturer's label: 'CIG [logo] / [blank weights table] / DRY / NITROUS OXIDE / C.I.G. (Victoria) PTY. LTD. / 50 LA TROBE STREET, MELBOURNE C3 / Telephones: FJ 6681 / FJ 4164 / USE NO OIL / OR GREASE'nitrous oxide, dental anaesthesia, dental anesthesia, gardner quincy colton, colton dental association -
Geoffrey Kaye Museum of Anaesthetic History
Anaesthetic, Novocain, The Saccharin Corporation Ltd
Novocaine is a local anaesthetic for dentistry. Its first known use was 1906. Square brown glass bottle with round neck and organ rubber stopper. A strand of wire has been wound around the stopper. A discoloured white manufacturer's label is stuck to the front of the bottle with black and red printed text. There is approximately half the liquid remaining in the bottle. Moulded into the bottom of the bottle: J282novocaine, drug, liquid, the saccharin corporation ltd, london, melbourne, j.l. brown & co, local anaesthetic -
National Vietnam Veterans Museum (NVVM)
Photograph, Sweet Dreams
A black and white photograph of Sister June Minchow is quietly amused by the facial expression of the Digger in the triage at the 1st Australian Field Hospital, Vung Tau, South Vietnam. This young Digger's reaction to the anaesthetic apppears to indicate a very happy and satisfying dream.photograph, 1st australian field hospital, vung tau, digger, capt june minchow, gibbons collection catalogue, nurse -
Geoffrey Kaye Museum of Anaesthetic History
Album - Photograph album, Rupert Hornabrook
This photo album depicts a small period of time during 1919, and highlights some of the anaesthetic work conducted by Dr Rupert Hornabrook. There is no record as to the reason for the construction of the album, but it appears to offer insight into his work the Dental School, as well as experimentation with different types of anaesthetic agents, using himself as a test subject.Rupert Hornabrook was an early full-time anaesthetist in Australia. He helped to develop anaesthesia into a specialised field of medicine by conducting research into the way anaesthesia worked, and its effects on the body. This album is of historic significance as it not only documents a specific period in the professional life of a full-time anaesthetist in Australia, it also documents anaesthetic equipment, and the way it was used.Blue photograph album with vinyl wrapped heavy card cover. A three ringed binder is attached to the inside of the album and sixteen (16) photographs are inside, mounted on heavy card. Each photograph has a typed label on white paper in blue ink adhered to the front describing the events of the photograph. Photographs depict various administrations of ethyl chloride as anaesthesia and analgesia, with many photographs of Rupert Hornabrook. -
Geoffrey Kaye Museum of Anaesthetic History
Book, Catalogue, Medical and Industrial Equipment, Anaesthesia Equipment
Undated catalogue outlining anaesthetic apparatus designed and supplied by MIE (Medical and Industrial Equipment), London.Blue cardboard covered book with low sheen white pages. Bound using staples through the spine and star pins. -
Geoffrey Kaye Museum of Anaesthetic History
Laryngoscope, Magill, 1926
Ivan Magill (1888-1986) designer, this piece was designed in 1926 along with other anaesthetic equipment.Chrome plated straight complete Magill laryngoscope in medium size format, with attached light bulb. Cylindrical handle for battery deposit and with a wavy hand grip for easy handling. Serrated and screwed lids on top and base of the handle grip for insertion of batteries and checking of electrical contact stud. The handle also has a metallic switch without any instruction of use. The arm of the handle has a detachable screw to adjust extendable blade position and firmness. The light bulb is attached to a metallic tube connector to the handle arm which is just pressed to the contact point base. The blade has a oxidation spot under the blade. The piece in full has several scratches marks mostly founded in handle, arm and top blade areas. Two stamped inscriptions are present on the arm area, the manufacturer name and register number.Stamped on the arm of the handle lateral side, A.CHARLES KING Stamped on the arm of the handle opposite lateral side, REG. NO. 74901[9]magill, a. charles king ltd, regi. no. 749019, switch, laryngoscope -
Geoffrey Kaye Museum of Anaesthetic History
Photograph
Black and white photograph of the front view of an anaesthetic machine, labelled the Killian Apparatus. Glass flowmeters with four cylinders are on top of a white metal stand on castors. Hanging from the top of the machine are tubes connected to an inhaler bag with a netbag around it. A metal stool is to the right of the machine.Handwritten in black ink on surface: THE KILLIAN APPARATUS.anaesthetic apparatus, anaesthetic machine, killian apparatus -
Royal Australian and New Zealand College of Obstetricians & Gynaecologists (RANZCOG)
'Waite's' cartridge type syringe used by Dr Lorna Lloyd-Green
Topacain is a surface contact anaesthetic for dental procedures. This object would have been used for dentistry procedures.A kit, containing a brass cartridge syringe with three cartridges. One cartridge [with red and white label lettering], contains eleven hypodermic needles. A second cartridge is labelled "Topacain".anaesthesia -
Geoffrey Kaye Museum of Anaesthetic History
Ethyl chloride inhaler, Mid 20th Century
The item was collected by Dr Geoffrey Kaye from a Vichy French military hospital during World war II.The inhaler comprises a black rubber face mask that connects to a metal circular chamber from which two white rubber valves are used to administer the anaesthetic agent. The ethyl chloride vials are labelled 'Kelene', a brand name. A waxed paper rebreather bag is attached to this metal chamer. mask, gas, anaesthesia, rebreather bag, world war ii, dr geoffrey kaye, ethyl chloride, kelene, french, vichy -
Geoffrey Kaye Museum of Anaesthetic History
Bottle, Chloroform
Chloroform began to be used as an anaesthetic agent in 1847. It was administered by dropping the substance on to a handkerchief held over the patient's nose and mouth.Clear glass bottle with frosted neck and fluted lip with a glass lid that has a frosted stopper and heart shaped handle piece for lifting the lid out of the bottle. The bottle is housed in a black circular cardboard case with red inner lining. Cotton padding has been stuffed in the top of the lid to protect the bottle stopper.Printed in gold leaf on top of case lid: CHLOROFORMchloroform, anaesthesia, surgery, administration -
Geoffrey Kaye Museum of Anaesthetic History
Photograph
Black and white photograph of an anaesthetic machine, likely to be a portable Foregger anaesthesia apparatus. Flowmeters with glass cylinders including Oxygen and Nitrous Oxide sit on a metal benchtop of a trolley with two drawers. A glass vaporiser is attached undernath the metal benchtop and there are metal valves attached on either side of the benchtop.anaesthetic apparatus, anaesthetic machine, foregger anaesthesia apparatus, flowmeter -
Geoffrey Kaye Museum of Anaesthetic History
Photograph
Black and white photograph of the side view of an anaesthetic machine, the Killian Apparatus. A glass flowmeter is on top of a white metal stand on castors. Hanging from the top of the machine are tubes connected to an inhaler bag with a netbag around it and a mouthpiece. A glass bottle is attached behind the machine and a metal stool is to the right of the machine.Handwritten in black ink on surface: THE KILLIAN APPARATUS.anaesthetic machine, anaesthetic apparatus, killian apparatus -
Geoffrey Kaye Museum of Anaesthetic History
De Ford Somniform Inhaler, E. De Trey & Sons Philadelphia, Pennsylvania, USA
The De Ford Inhaler was introduced in 1913 and was designed to allow anaesthesia to continue through the nose while dental surgery was happening.This inhaler is composed of metal and rubber. The oral mask and rubber covered nasal mask are connected to a curved rubber covered support that was placed on the patient's forehead to hold the inhaler in place. The gas was administered via a long tube; the terminus designed to allow for the placement of a vial containing the anaesthetic drug and a rebreather bag mount. Inscribed on the back of the mouth inhaler: 'Dr De Ford's Universal Inhaler for Somniform Nitrous Oxide etc. E. De Trey & Sons Phila. PA U.S. Pat. Pending.'anesthesia, dentistry, somniform, surgery, medical instrument, de ford, 1913, e de trey and sons, vial, rebreathr bag mount, inhaler -
Royal Australian and New Zealand College of Obstetricians & Gynaecologists (RANZCOG)
Tool - Guy's tongue forceps used by Dr Mitchell Henry O'Sullivan, 1930 (approximate)
During surgery under general anaesthetic, these forceps were used to pull the tongue forward to keep the patient's airways clear from obstruction. This tool was in general use from the 1930s onwards in teaching hospitals, and became a standard piece of equipment on all anaesthetic trolleys. In the majority of teaching hospitals, the blades of these forceps were smooth and wide to cause less trauma to the tongue. This particular style of tongue forceps is known as Guy's tongue forceps.Dr Mitchell Henry O'Sullivan worked in the Victorian country town of Casterton as a general practitioner from 1919 until his death in 1977. He also practiced obstetrics. His son, Dr David More O'Sullivan donated his obstetric bag and its contents to the College in 1999. The bag and contents are a unique time capsule of the type of instruments and pharmaceuticals used in the inter-war period.Pair of metal forceps. Similar in appearance to a pair of scissors, and other surgical forceps, but with rounded teardrop shaped tips. There is also a notch clip for the handle to keep the forceps open. Inner aspect of both forceps blades engraved with the number '3'. The left hand blade is also engraved with a 'P'.anaesthesia -
Warrnambool and District Historical Society Inc.
Book, Fifty Years of Remedies Bayer 1888-1938, 1938
Remedies available from Bayer PharmaceuticalsThis is a book of 90 pages, The cover is beige with embossed white and gold printing. The spine is somewhat worn. The pages contain printed text and black and white photographs and illustrationsnon-fictionRemedies available from Bayer Pharmaceuticalsbayer company of germany, pharmaceuticals -
Geoffrey Kaye Museum of Anaesthetic History
Equipment - Sight Feed Type Water Depression Flowmeter, 1925
This object dates back to 1925 and was sectioned by Dr Geoffrey Kaye in 1938. Flowmeters were attached to an anaesthetic machine to measure the flow rate of gas or liquid.Metal cylinder with glass inner chamber and gauge inside. The object has been sectioned for teaching purposes.Manufacturer's marks and instructions on the top screw valve state, K/38, Screw Lightly, Oxygen Fine. Direct Ox. is inscribed on the back of the top valve. G.Kaye fecit. 1938 is inscribed in handwriting on the top of the flowmeter tube. flowmeter, water depression, gas, sectioned, slight feed, anaesthetic machine -
Geoffrey Kaye Museum of Anaesthetic History
Bottle, Ethyl Chloride, Medicinal Chemicals Corporation Pty. Ltd, c. 1932
Ethyl chloride was first used as a general anaesthetic in 1847, by Johann Ferdinand Heyfelder (1798-1869), a German surgeon. Once ethyl chloride became readily available, it was again taken up as a general anaesthetic in the late 1890s (USA). Ethyl chloride evaporates very quickly so that when it is sprayed onto the skin it produces very cold temperatures. “Refrigeration anesthesia”, or cryoanesthesia, refers to the anesthesia produced when the skin is significantly cooled.Due to its rapid onset, ethyl chloride was often used to induce general anaesthesia. It would be followed by a second anaesthetic, such as ether or nitrous oxide, which would be used for the remainder of the procedure. (The Wood Library Museum, 2016) The bottle has clear side and base mould seams which indicate it was made using a cup bottom mould.Glass bottle with paper label, metal fastening at the top and cream coloured plastic sealant at the neck. The bottle has clear side and base mould seams which indicate it was made using a cup bottom mould.Printed on main label at front: 100 c.c. 3 1/2 fl. ozs. / MEDICINAL CHEMICALS CORP [illegible] / MEDCO / ETHYL CHLORIDE / PURE / This Product conforms to all the re-/quirements of the BRITISH PHARMA-/COPCEIA, 1932, for / GENERAL ANAESTHESIA / Manufactured by / MEDICINAL CHEMICALS CORPORATION PTY. LIMITED / 39 Martin Place, Sydney Printed on round label on reverse side: 6d. / Cred [illegible]this container if returned in good order and condition. Stamped into underside of bottle: CM / S99ethyl chloride, medco, medicinal chemicals corporation pty. ltd, dr [e.s] holloway, bottle -
Kiewa Valley Historical Society
Bottle - Medical
This bottle was used in the Tawonga District General Hospital which was built in the 1950's specifically for the increase in population due to the Kiewa Hydro Scheme.Clear glass bottle with glass stopper that has string around it and the bottle so remaining attached when taken out. The fitted part of the stopper is opaque as is that part of the neck into which it fits. The neck is short. Base is embossed. Used for anaesthetic possibly ether. It may have had a special cork with dripper on it to drop on the mask.Base: 'L 75 / M / Common Seal'anaesthetic bottle, medical, hospital