Geoffrey Kaye Museum of Anaesthetic History
Photograph
Robert James Minnitt introduced the concept of self-administered analgesia, using an apparatus designed and built in conjunction with London scientific instrument-maker, Charles King. The Minnitt apparatus met with considerable success and led to further modifications, including the introduction of the Queen Charlotte gas-air analgesia apparatus in 1936, manufactured by the British Oxygen Company.Black and white photograph of a Minnitt gas/air analgesia apparatus, in a Queen Charlotte case. The case is standing open with the apparatus inside. A label with instructions is on the left side of the case, and the apparatus is on the right side of the case. A nitrous oxide cylinder tank and valve is connected to a small box with a regulator. A tube with a breathing mask is attached to the box. The Queen Charlotte case has hinges on the side and a handle on the top.minnitt gas air apparatus, minnitt, nitrous oxide, queen charlotte case, anaesthetic equipment -
Geoffrey Kaye Museum of Anaesthetic History
Photograph
Black and white photograph of a drawing of anaesthetic equipment, a flowmeter and an ether vaporiser. On the right is the ether vaporiser inside a glass cylinder, with a control tap on top of it. It is attached to a metal cylinder which houses the flowmeter which is measuring the Oxygen and Nitrous Oxide. There is a round Oxygen control and a Nitrous Oxide control attached underneath the metal cylinder, as well as an Oxygen Bypass and a Nitrous Oxide Bypass. The diagram has each part of the apparatus named with an arrow pointing to the parts.ether vaporiser, anaesthetic equipment, flowmeter, nitrous oxide, oxygen -
Geoffrey Kaye Museum of Anaesthetic History
Photograph
Black and white photograph of the head of a portable Foregger "Metric" Gas Anaesthesia Apparatus. The apparatus has glass flowmeters and controls for fine and coarse oxygen, cyclopropane, nitrous oxide and carbon dioxide. There is also an ether container and a blood pressure nanometer.•Handwritten in grey pencil on reverse: Dr. Desai's Special Metric •Handwritten in black ink on reverse: III. •Handwritten in grey pencil on reverse: dvpd.anaesthetic equipment, anaesthetic machine, flowmeter, foregger metric gas anaesthesia apparatus, oxygen, nitrous oxide, carbon dioxide, cyclopropane -
Geoffrey Kaye Museum of Anaesthetic History
Mask, Julliard, 1877
This is a large metal framework covered in gauze, the whole mask completely enclosing the patient's face excluding any possibility of carbon dioxide being excreted. This object was found in the possession of the Italian Army in Libya in 1940, and donated to the museum by Dr Geoffrey Kaye. Gustave Julliard, of Geneva, after a death from chloroform had occurred in his practice, abandoned the use of that anaesthetic and adopted ether. He administered it from a large, wire frame, the outside of which was covered with waxed cloth to make it impermeable to air, the inside with surgical gauze on to which the ether was poured. Large metal wire frame mask, covered in waxed paper, with gauze wrapped around the rim to prevent ether leaking out, effectively forming a rebreathing apparatus.ether, carbon dioxide, italian army, libya, 1940 -
Geoffrey Kaye Museum of Anaesthetic History
Equipment - Junker's apparatus
Between 1867 and 1920, anaesthesia for dental operations was often maintained by blowing the vapour of ether or chloroform into the patients' oral or nasal pharynx. Junker's inhalers are a "blow over" device used with a hand-held bellows to bubble air through liquid chloroform and to the patient. It was initially intended for use with bichloride of methylene, a mixture of chloroform and methyl alcohol. Ferdinand Ethelbert Junker introduced his inhaler in 1867 as appointed physician to Samaritan Free Hospital for Women (although it didn't have that name until c.1904). Glass jar with liquid measure markers etched onto. The jar has a metal lid, with a metal tube descending into the jar. Two metal tubes are protuding out of the top of the lid, and each has a small section of rubber tubing attached. There is also a metal hook, used to attached the jar to the physicians (anaesthetist's) lapel.Stamped into frame of metal lid: LONDON MADEjunker, blow over, chloroform, samaritan free hospital for women -
Geoffrey Kaye Museum of Anaesthetic History
Equipment - SS White nitrous oxide/oxygen apparatus
With the introduction of nitrous oxide for patients undergoing dental treatment, 100% nitrous oxide was usually administered as an anaesthetic. This caused the patient to lose consciousness quickly and could also cause severe hypoxia. In the late 1890s, dentist Samuel Stockton White introduced this two cylinder apparatus, which could administer oxygen with N2O.Early model apparatus with cast iron stand, and two gas bottles. Comes with two canvas gas bags and a detached metal mask and fabric connecting tube.samuel stockton white, nitrous oxide, oxygen, hypoxia