Showing 335 items
matching forests commission victoria (fcv)
-
Department of Energy, Environment and Climate Action
Rega fire knapsack for use with bulldozer
... Forests Commission Victoria (FCV)..., including smaller knapsacks. Forests Commission Victoria (FCV ...Spraying units were manufactured in Australia by REGA Products Ltd. from 1926. REGA established themselves as leaders in the production of agricultural and horticultural spraying machines, including smaller knapsacks.Plastic fire knapsack usually attached to the back of machinery Brass pump handle and adjustable nozzle attached.REGAforests commission victoria (fcv), bushfire, planned burning, fire pump -
Department of Energy, Environment and Climate Action
Rega fire knapsack for use with bulldozer
... Forests Commission Victoria (FCV)..., including smaller knapsacks. Forests Commission Victoria (FCV ...Spraying units were manufactured in Australia by REGA Products Ltd. from 1926. REGA established themselves as leaders in the production of agricultural and horticultural spraying machines, including smaller knapsacks.Metal fire knapsack usually attached to the back of machinery Brass pump handle and adjustable nozzle attached.REGAforests commission victoria (fcv), bushfire, planned burning, fire pump -
Department of Energy, Environment and Climate Action
Hose winding tool
... Forests Commission Victoria (FCV)...After the 1939 bushfires the Forests Commission placed ...After the 1939 bushfires the Forests Commission placed orders for 130,000 feet (nearly 40 km) of 1½ inch canvas hose in Britain to accompany over 200 new pumps of various types. The Altona workshop became a major centre for fabrication, repair and storage of hose. But lack of standardisation of hose couplings plagued Australian firefighters for decadesHose reel holder winder for canvas hoses Canvas hose needs to be washed, dried, rolled and stored properly after it has been used otherwise it will rot. Unrolled hose is notorious for becoming tangled.FCVforests commission victoria (fcv), bushfire, fire pump, fire tanker -
Department of Energy, Environment and Climate Action
Hose reel holder
... Forests Commission Victoria (FCV)...After the 1939 bushfires the Forests Commission placed ...After the 1939 bushfires the Forests Commission placed orders for 130,000 feet (nearly 40 km) of 1½ inch canvas hose in Britain to accompany over 200 new pumps of various types. The Altona workshop became a major centre for fabrication, repair and storage of hose. But lack of standardisation of hose couplings plagued Australian firefighters for decadesHose reel holder with two 1&1/2 inch and one 2&1/2 inch canvas hosesforests commission victoria (fcv), bushfire, fire pump, fire tanker -
Department of Energy, Environment and Climate Action
Figure 8 hose winding tool
... Forests Commission Victoria (FCV)...After the 1939 bushfires the Forests Commission placed ...After the 1939 bushfires the Forests Commission placed orders for 130,000 feet (nearly 40 km) of 1½ inch canvas hose in Britain to accompany over 200 new pumps of various types. The Altona workshop became a major centre for fabrication, repair and storage of hose. But lack of standardisation of hose couplings plagued Australian firefighters for decadesFigure 8 hose reel holder winder for canvas hoses Canvas hose needs to be washed, dried, rolled and stored properly after it has been used otherwise it will rot. Unrolled hose is notorious for becoming tangled.FCVforests commission victoria (fcv), bushfire, fire pump, fire tanker -
Department of Energy, Environment and Climate Action
Hose pressure testing kit
... Forests Commission Victoria (FCV)...After the 1939 bushfires the Forests Commission placed ...After the 1939 bushfires the Forests Commission placed orders for 130,000 feet (nearly 40 km) of 1½ inch canvas hose in Britain to accompany over 200 new pumps of various types. The Altona workshop became a major centre for fabrication, repair and storage of hose. But lack of standardisation of hose couplings plagued Australian firefighters for decadesHose pressure testing kit. Canvas hose needs to be washed, dried, rolled and stored properly after it has been used otherwise it will rot. Unrolled hose is notorious for becoming tangled.FCVforests commission victoria (fcv), bushfire, fire pump, fire tanker -
Department of Energy, Environment and Climate Action
Hose clamps (various)
... Forests Commission Victoria (FCV)...After the 1939 bushfires the Forests Commission placed ...After the 1939 bushfires the Forests Commission placed orders for 130,000 feet (nearly 40 km) of 1½ inch canvas hose in Britain to accompany over 200 new pumps of various types. The Altona workshop became a major centre for fabrication, repair and storage of hose. But lack of standardisation of hose couplings plagued Australian firefighters for decadesTools used to clamp canvas hose for testing. Canvas hose needs to be washed, dried, rolled and stored properly after it has been used otherwise it will rot. Unrolled hose is notorious for becoming tangled.FCVforests commission victoria (fcv), bushfire, fire pump, fire tanker -
Department of Energy, Environment and Climate Action
Hose basket
... Forests Commission Victoria (FCV)...After the 1939 bushfires the Forests Commission placed ...After the 1939 bushfires the Forests Commission placed orders for 130,000 feet (nearly 40 km) of 1½ inch canvas hose in Britain to accompany over 200 new pumps of various types. The Altona workshop became a major centre for fabrication, repair and storage of hose. But lack of standardisation of hose couplings plagued Australian firefighters for decadesWicker basket used on the end of suction hose to stop debris entering the pump forests commission victoria (fcv), bushfire, fire pump, fire tanker -
Department of Energy, Environment and Climate Action
Hose key
... Forests Commission Victoria (FCV)...After the 1939 bushfires the Forests Commission placed ...After the 1939 bushfires the Forests Commission placed orders for 130,000 feet (nearly 40 km) of 1½ inch canvas hose in Britain to accompany over 200 new pumps of various types. The Altona workshop became a major centre for fabrication, repair and storage of hose. But lack of standardisation of hose couplings plagued Australian firefighters for decadesTools used undo brass coupling on canvas hose Canvas hose needs to be washed, dried, rolled and stored properly after it has been used otherwise it will rot. Unrolled hose is notorious for becoming tangled.FCVforests commission victoria (fcv), bushfire, fire pump, fire tanker -
Department of Energy, Environment and Climate Action
Canvas hose roll holder (various)
... Forests Commission Victoria (FCV)...After the 1939 bushfires the Forests Commission placed ...After the 1939 bushfires the Forests Commission placed orders for 130,000 feet (nearly 40 km) of 1½ inch canvas hose in Britain to accompany over 200 new pumps of various types. The Altona workshop became a major centre for fabrication, repair and storage of hose. But lack of standardisation of hose couplings plagued Australian firefighters for decadesHolders to carry canvas hose rolls Canvas hose needs to be washed, dried, rolled and stored properly after it has been used otherwise it will rot. Unrolled hose is notorious for becoming tangled.forests commission victoria (fcv), bushfire, fire pump, fire tanker -
Department of Energy, Environment and Climate Action
Hose vulcaniser
... Forests Commission Victoria (FCV)...After the 1939 bushfires the Forests Commission placed ...After the 1939 bushfires the Forests Commission placed orders for 130,000 feet (nearly 40 km) of 1½ inch canvas hose in Britain to accompany over 200 new pumps of various types. The Altona workshop became a major centre for fabrication, repair and storage of hose. But lack of standardisation of hose couplings plagued Australian firefighters for decadesUsed to repair canvas hose A rubber patch is placed over the hole in the hose and clamped. It is then heated electrically to melt the rubber patch Canvas hose needs to be washed, dried, rolled and stored properly after it has been used otherwise it will rot. Unrolled hose is notorious for becoming tangled.forests commission victoria (fcv), bushfire, fire pump, fire tanker -
Department of Energy, Environment and Climate Action
Hose coupling tool
... Forests Commission Victoria (FCV)...After the 1939 bushfires the Forests Commission placed ...After the 1939 bushfires the Forests Commission placed orders for 130,000 feet (nearly 40 km) of 1½ inch canvas hose in Britain to accompany over 200 new pumps of various types. The Altona workshop became a major centre for fabrication, repair and storage of hose. But lack of standardisation of hose couplings plagued Australian firefighters for decadesUsed to attach couplers to canvas hose The tool is held in a large clamp and stretches the coupler onto the hose. A tension bar is used to control leverage Canvas hose needs to be washed, dried, rolled and stored properly after it has been used otherwise it will rot. Unrolled hose is notorious for becoming tangled.Warren Brownforests commission victoria (fcv), bushfire, fire pump, fire tanker -
Department of Energy, Environment and Climate Action
Peat Spears (various)
... Forests Commission Victoria (FCV)... Commission Victoria (FCV) Bushfire Fire Pump Fire tanker Underground ...After the 1939 bushfires the Forests Commission placed orders for 130,000 feet (nearly 40 km) of 1½ inch canvas hose in Britain to accompany over 200 new pumps of various types. The Altona workshop became a major centre for fabrication, repair and storage of hose, pumps and specialised equipment.Underground peat fires are very difficult to extinguish Water tends to just run off and not penetrate when sprayed onto the surface Peat spears are driven into the ground and connected to high pressure hose to inject waterforests commission victoria (fcv), bushfire, fire pump, fire tanker -
Department of Energy, Environment and Climate Action
REGA Hose key
... Forests Commission Victoria (FCV)...After the 1939 bushfires the Forests Commission placed ...After the 1939 bushfires the Forests Commission placed orders for 130,000 feet (nearly 40 km) of 1½ inch canvas hose in Britain to accompany over 200 new pumps of various types. The Altona workshop became a major centre for fabrication, repair and storage of hose. But lack of standardisation of hose couplings plagued Australian firefighters for decadesRega hose keyREGAforests commission victoria (fcv), bushfire, fire pump, fire tanker -
Department of Energy, Environment and Climate Action
SIMAC hand pump
... Forests Commission Victoria (FCV)...Forests Commission Victoria (FCV) Fire Pump Bushfire SIMAC ...Hand water pumpSIMACforests commission victoria (fcv), fire pump, bushfire -
Department of Energy, Environment and Climate Action
Dennis Fire pump 1921
... Forests Commission Victoria (FCV)... Commission Victoria (FCV) Fire Pump Bushfire Dennis Turbine engine ...Was recovered from the Forestry School at CreswickDennis Turbine engine fire pump Guildford motor Dated April 15 1921forests commission victoria (fcv), fire pump, bushfire -
Department of Energy, Environment and Climate Action
Coventry Climax Pump FSM
... Forests Commission Victoria (FCV)... of WW2. Fire pump Forests Commission Victoria (FCV) Coventry ...Among the many pressing priorities for Alf Lawrence, the Forests Commission's new Chief Fire Officer, in rebuilding the firefighting capacity after the catastrophic 1939 bushfires was to invest heavily in modern vehicles and equipment. Powered pumps like the trailer-mounted Coventry Climax (Godiva) gave firefighters a much greater capacity than ever before to put the “wet stuff on the red stuff”. Its four-cylinder, four-stroke, water-cooled, petrol motor produced 38Hp and was connected with either 1½ inch or 2½ inch canvas hose for direct attack, or as a filler pump it could deliver 300 gallons per minute at 120 psi. Some of the first acquisitions included this war surplus veteran shipped over from the London after the blitz bombings of WW2. Fire pump mounted on trailer Two lengths of suction hose, nozzles and some tools.Coventry Climax Serial 3844 FCV No 24fire pump, forests commission victoria (fcv) -
Department of Energy, Environment and Climate Action
Johnston Tremblay HOK pump
... Forests Commission Victoria (FCV)...Forests Commission Victoria (FCV) Bushfire Fire Pump High ...High pressure Johnston Tremblay HOK pump. It was invented in about 1940 by Mr. J. Tremblay, fire-chief & director of public safety for Montreal forests commission victoria (fcv), bushfire, fire pump -
Department of Energy, Environment and Climate Action
Pacific Marine pump Type Y
... Forests Commission Victoria (FCV)... of choice for forest firefighters in the 1980s. Forests Commission ...The Pacific Marine company was based in Seattle on the west coast of America and manufactured its first satisfactory portable fire pump 1925. These early Type N pumps were replaced in 1933 by the more familiar Type Y pumps. The updated pumps proved popular with the US Forest Service, and a large number were purchased by the Forests Commission as part of the equipment upgrade program in the wake of the 1939 bushfires. The Pacific Marine had a 9.8 Hp, two-cylinder, two-stroke petrol motor running with a high oil mix ratio of 16:1, so it blew vast clouds of blue smoke as the motor screamed at 4500 rpm. Part of its unique design was the water-cooled engine and muffler. But if the flow of water was interrupted the engine would quickly overheat and seize, so it needed constant monitoring and attention. Water was driven through a pair of bronze impeller gears which also needed a constant flow of water otherwise they would also self-destruct. When running properly, a Pacific Marine could pump 63 US gallons per minute, or about enough to fill a 200-litre drum. But its main feature was its high pressure of up to 225 psi. Pacific Marine pumps were often mounted on top of departmental fire tankers and used to spray water into the tops of burning trees. Compared to other pumps of the era it was light weight at only 70 pounds and was often mounted on a wooden stretcher frame. But they were cantankerous things to start with the rope pull and many exasperated novices came away with skinned knuckles. Modern Honda motors, which were more reliable and smoother running, replaced the Pacific Marines as the pump of choice for forest firefighters in the 1980s.High pressure Pacific marine Pumpforests commission victoria (fcv), bushfire, fire pump -
Department of Energy, Environment and Climate Action
Sigmund Pump
... Forests Commission Victoria (FCV)... factory. Forests Commission Victoria (FCV) Fire Pump Bushfire ...In 1937 Sigmund Pumps company founded by Miroslav Sigmund, in Czechoslovakia; and successfully tendered for a British government contract to make firefighting pumps. In 1938 they moved to Britain soon after Hitler's annexation of Austria. Sigmund Pumps (Great Britain) Ltd was founded at the Team Valley trading estate in Gateshead By 1939, 3000 pumps had been manufactured at the new factory.Sigmund two handle pump with hoseSigmund Pumps (Great Britain)forests commission victoria (fcv), fire pump, bushfire -
Department of Energy, Environment and Climate Action
Wajax Mk 3 pump
... Forests Commission Victoria (FCV)... that time has undergone several upgrades Forests Commission Victoria ...The earlier Pacific Marine pumps were not replaced and were auctioned off during the 1980s. The ever reliable Wajax Mk3 remained a fire cache item ready to be called on should a specific need for a small transportable pressure pump arise. The Wajax Mk3 has been in circulation since the 1950’s, and through that time has undergone several upgradesHigh pressure Wajax Mk 3 pump With hand primerforests commission victoria (fcv), bushfire, fire pump -
Department of Energy, Environment and Climate Action
Rex Pump
... Forests Commission Victoria (FCV)...Forests Commission Victoria (FCV) Fire Pump Bushfire REX ...REX Fire Pumpforests commission victoria (fcv), fire pump, bushfire -
Department of Energy, Environment and Climate Action
Sigmund Pump
... Forests Commission Victoria (FCV)... factory. Forests Commission Victoria (FCV) Fire Pump Bushfire ...In 1937 Sigmund Pumps company founded by Miroslav Sigmund, in Czechoslovakia; and successfully tendered for a British government contract to make firefighting pumps. In 1938 they moved to Britain soon after Hitler's annexation of Austria. Sigmund Pumps (Great Britain) Ltd was founded at the Team Valley trading estate in Gateshead By 1939, 3000 pumps had been manufactured at the new factory.Sigmund two handle pump level pumpforests commission victoria (fcv), fire pump, bushfire -
Department of Energy, Environment and Climate Action
Gaam 30B pump
... Forests Commission Victoria (FCV)... Altona in the early 1960s. Forests Commission Victoria (FCV) Fire ...The Gaam 30B pump delivers 80 Gallons per minute @ 80 PSI The original Howard engine, equipped with a rope start, could be temperamental and difficult to start on occasions, and were replaced with an electric start 7 HP Wisconsin motor. This modification was designed and installed by the FCV Fire Protection Workshop at North Altona in the early 1960s.Wisconsin 7HP motor coupled to a Gaam 30B pump With hand primerforests commission victoria (fcv), fire pump, bushfire -
Department of Energy, Environment and Climate Action
Litster pump (rare)
... Forests Commission Victoria (FCV)...Forests Commission Victoria (FCV) Fire Pump Bushfire Lister ...Lister fire pump on wooden carry cradle With suction hoseListerforests commission victoria (fcv), fire pump, bushfire -
Department of Energy, Environment and Climate Action
Alcon 3 inch filler pump
... Forests Commission Victoria (FCV)...Forests Commission Victoria (FCV) Fire Pump Bushfire Alcon ...Alcon fire pump with Briggs and Stratton motor on metal carry cradleforests commission victoria (fcv), fire pump, bushfire -
Department of Energy, Environment and Climate Action
Lamp for Coventry Climax pump trailer
... Forests Commission Victoria (FCV)...Forests Commission Victoria (FCV) Fire Pump Bushfire Lamp ...Lamp fitted to Coventry Climax pump trialerforests commission victoria (fcv), fire pump, bushfire -
Department of Energy, Environment and Climate Action
Slip-on unit with foam injection system
... Forests Commission Victoria (FCV)...Forests Commission Victoria (FCV) Fire Pump Bushfire Foam ...Foam injection slip on unit mounted on a sloping frame for training and demonstration purposes This technology was developed at Altona in the 1990sforests commission victoria (fcv), fire pump, bushfire -
Department of Energy, Environment and Climate Action
Bedford M Series fire tanker
... Forests Commission Victoria (FCV)... tanker Forests Commission Victoria (FCV) MZF 347 Bedford M series ...Ash Wednesday Veteran This Bedford M Series tanker spent its working days at the Forests Commission depot at Gembrook, and among its many forays, fought the deadly Ash Wednesday bushfires at nearby Upper Beaconsfield and Cockatoo on 16 February 1983. Earlier in 1975, the M Series tankers underwent a design change at the Altona North workshops, replacing the cylindrical water tank with a “V” bottom 4090 litre water tank that sat low between the chassis rails to reduce its centre of gravity. Aluminium heat shields were also added to protect the pump operators on the back. While generally considered "bulletproof" the petrol fuel lines on this particular model were very prone to vaporise in the heat causing the motor to stall, often at the most dangerous moment.... in this case frightening the hell out of its driver, affable knockabout bloke, and firefighting legend Lex Wade. Some jokingly said this design quirk was an inbuilt safety feature to stop crews getting too close to the fire in the first place. The Gembrook tanker was later sent into the workshop and all its brake and fuel lines fitted with heat resistant lagging. Fortunately, this remarkable bushfire survivor was rescued from the scrap heap by Lex and fire equipment wizard Barry Marsden upon its retirement from a loyal and lengthy service. After a lick of fresh paint and most of its battle scars "buffed out", this time-honoured veteran now takes pride of place at the Altona North workshop.Bedford M series fire tankerMZF 347fire pump, fire tanker, forests commission victoria (fcv) -
Department of Energy, Environment and Climate Action
Display board
... Forests Commission Victoria (FCV).... Forests Commission Victoria (FCV) Bushfire Bushfire Aviation Large ...The Forests Commission and its successors continuously encouraged bushfire research and innovation. In 1946 a large parcel of industrial land was purchased at North Altona as a fire cache and workshop. The Altona workshop became a hotbed of new technological innovation… an exhilarating place where lots of things were invented and tested. In fact, a lot of Australia’s pioneering equipment development was led by staff from Altona, often in collaboration with other State forestry and fire authorities. The CSIRO also contributed significantly. The US Forest Service, the US Bureau of Land Management and US State agencies such as the California Department of Forestry and Fire (CalFire) as well as the Canadian Forest Service faced similar challenges and proved strong and willing partners in sharing knowledge, ideas, equipment and expertise over many decades. This collection of badges is testament to the relationships that were forged across the globe with the Altona workshop. Large display panel featuring many fire service badgesforests commission victoria (fcv), bushfire, bushfire aviation