Showing 1416 items
matching attached houses
-
Geoffrey Kaye Museum of Anaesthetic History
Inhaler, Analgesia, Penthrane
Originally distributed by Abbott Laboratories. This device is used for the self-administration of Penthane, an analgesic. Designed for use in emergency rooms, obstetrics, orthopaedics and surgical outpatients.Wooden box with metal clasp and hinges and two sections inside, divided by balsa wood. One side contains an amber plastic and black rubber facial mask, along with a inhaler tube and felt square. The other side contains a cylindrical metal device with a black plastic handle secured to one end and a portal for attaching the facial mask at the other.penthrane, analgesia, self-administration -
Geoffrey Kaye Museum of Anaesthetic History
Laryngeal Mask Airway, Mallinckrodt
Blue transparent plastic tubing with a clear plastic laryngeal mask attached. There is an additional fine tube threaded through the blue tubing toward the mask opening.Printed in black ink on blue plastic tube: SIZE / 2.5 / MALLINCKRODT LaryngoSeal TM / Single Use Only 20 - 30kglaryngeal mask airway, brain, archive, england, mallinckrodt, laryngoseal, endotracheal intubation -
Geoffrey Kaye Museum of Anaesthetic History
Laryngeal Mask Airway, Intavent
The Laryngeal Mask Airway was invented in 1983 by British anaesthetist, Archie Brain.Yellow plastic tubing with a pink rubber laryngeal mask attached. There is an additional fine yellow tube threaded through the base of the rubber mask. Printed in black in along side: #4 LARYNGEAL MASK AUTOCLAVABLE INTAVENT 3:1laryngeal, brain, archie, endotracheal intubation, autoclavable -
Geoffrey Kaye Museum of Anaesthetic History
Tube, Endotracheal, Uncuffed, A. Charles King Ltd, c.1932
This is an early example of an endotracheal tube (c.1932) invented by Ivan Magill. The shattered faces and jaws of wounded soldiers presented real difficulties for the administration of anaesthesia. Ivan Magill and Stanley Rowbotham developed endotracheal tubes for these procedures that were more efficient and practical than the earlier insufflation catheters.The attached safety pin was used to prevent the loss of the tube down the patient's nose. Orange/brown rubber tubing with a bevelled edge at one end a safety pin stuck through the other end. This tube was used for nasal endotracheal intubation.Printed in black ink on tube: NO. 5 NASAL A. CHARLES KING LTD. MAGILL'S TUBE 27 / BRITISH MADEmagill, endotracheal, intubation, nasal, a. charles king ltd, england -
Geoffrey Kaye Museum of Anaesthetic History
Tube, Endotracheal, Uncuffed Rubber Nasal Tube
This is an early example of an endotracheal tube invented by Ivan Magill. The shattered faces and jaws of wounded soldiers presented real difficulties for the administration of anaesthesia. Ivan Magill and Stanley Rowbotham developed endotracheal tubes for these procedures that were more efficient and practical than the earlier insufflation catheters.The attached safety pin was used to prevent the loss of the tube down the patient's nose.Brown rubber tubing with three pairs of holes at one end and a bevelled edge at the other for nasal endotracheal intubation. There is a large safety pin stuck through the first pair of holes.magill, ivan, endotracheal, intubation, nasal, airway -
Geoffrey Kaye Museum of Anaesthetic History
Tube, Pharyngeal, Cuffed, India Tyre and Rubber Company
This is an early example of a cuffed pharyngeal tube. The cuffed airway was a significant development in pharyngeal tubes as it helped to protect the airway from blood and secretions. Black rubber tubing with spiral metal inner tube and red rubber pump mechanism attachedMoulded onto rubber bulb: Tycos Moulded onto rubber connector: MADE ONLY FOR PATENTEE / INDIA TYRE AND RUBBER CO / INCHINNAN / SCOTLAND Moulded into metal connection: Tycos / LONDONpharyngeal, ndia rubber & tyre company, airway, cuffed, scotland, tycos -
Geoffrey Kaye Museum of Anaesthetic History
Equipment - Sight Feed Type Water Depression Flowmeter, 1925
This object dates back to 1925 and was sectioned by Dr Geoffrey Kaye in 1938. Flowmeters were attached to an anaesthetic machine to measure the flow rate of gas or liquid.Metal cylinder with glass inner chamber and gauge inside. The object has been sectioned for teaching purposes.Manufacturer's marks and instructions on the top screw valve state, K/38, Screw Lightly, Oxygen Fine. Direct Ox. is inscribed on the back of the top valve. G.Kaye fecit. 1938 is inscribed in handwriting on the top of the flowmeter tube. flowmeter, water depression, gas, sectioned, slight feed, anaesthetic machine -
Geoffrey Kaye Museum of Anaesthetic History
Bottle, Blood transfusion
Dr Alan Holmes á Court enlisted in the Australian Army in 1916 as a medical officer with the rank of Captain. In 1918, Holmes á Court was promoted to Major and attached to the 4th Australian Field Ambulance on the Western Front. As the front advanced, the Casualty Clearing Stations became further removed from the battlefield, creating an urgent need for immediate resuscitation prior to transfer back to the CCS. In June 1918, Holmes a Court and his colleagues established a forward resuscitation team. The team consisted of one doctor trained in surgery, blood transfusion and resuscitation, another doctor trained in anaesthesia, resuscitation and blood classification, and four other assisting staff. This team moved out to the wounded, rather than waiting for them to be stretchered back. They provided on-the-spot, life-saving resuscitation. The wounded were then transported back to the Casualty Clearing Station or Regimental Aid Post for further treatment. Among the assorted surgical and resuscitation equipment carried by the forward resuscitation team, were a number of Kimpton-Brown flasks. Blood was collected from patients with minor injuries using the flask. It was then administered to those in need, after establishing their blood type. Citrated blood was introduced by the Americans in 1917. This allowed blood administration to be delayed for up to two hours but there were many problems with transport, storage and infection in these early experimental days.Round, clear glass bottle with white [discoloured] paper label, with red printed, and metal screw-top lid.Handwritten on white [discoloured] paper label: Phillip HARRIS Moulded into the top of the screw-top lid in red ink: RED CROSS BLOOD TRANSFUSION SERVICEblood transfusion, red cross, world war one -
Geoffrey Kaye Museum of Anaesthetic History
Equipment - Bird Respirator Mark 7A with C.I.G. 'Ventviva' ventilator
The Bird ventilator Mark 7 is driven by medical compressed air or oxygen. It is not suited for anaesthesia unless using a special anaesthesia assistor controller attachment, which is essentially a “bag in a bottle” device.Apparatus attached to four castor stand with attached white wall connecting tubing.anaesthesia attachment, bag in a bottle -
Geoffrey Kaye Museum of Anaesthetic History
Bronchial Blocker, Macintosh Leatherdale Left Bronchial Blocker, 1955
This tube is designed for left pneumonectomy (surgical removal of a lung or part of a lung). The left stem bronchus may be completely blocked off, while the right lung is inflated. There is provision for aspiration of the left bronchus.Rubber tubing with curved and tapered end for insertion into lung. Three smaller tubes come off the larger end, two of which have small rubber valves attached. The tube appears with a banded effect however, the banding is represents the now disintegrated rubber cuff.Blue sticker with white writing on side of tube: S.I.6.bronchus, bronchial, blocker, pneumonectomy, macintosh, leatherdale -
Geoffrey Kaye Museum of Anaesthetic History
Needle
Brown cardboard box with buff coloured manufacturer's label adhered to front and cardboard slide tray containing a metal tray with seven (7) needles attached. The tray is surrounded by clear plastic.Handwritten in black ink on manufacturer's label: Short Bevelhypodermic, needle, syringe, the star, england, short bevel -
Geoffrey Kaye Museum of Anaesthetic History
Laryngoscope, Magill, A. Charles King Ltd, 1930
Magill laryngoscope with a battery in the handle was one of first of its kind This piece of equipment is made of stainless steel and has a canal on its left side and a handle to put batteries inside of it and it has attached a round screw to make it extendable. This object also has an stamped inscription and on the other side it has the manufacturer details. Stamped A.CHARLES KING.LTD Stamped REG.NO.749019 Stamped STAINLESSmagill, ivan, battery -
Geoffrey Kaye Museum of Anaesthetic History
Laryngoscope, MacIntosh
Curved laryngoscope blade and handle. The laryngoscope blade is identified as a MAC 3 RIESTER blade and is attached to the textured handle with a serrated grip for ease of use. The handle is also a battery deposit which has stamped on the lid base the manufacturer's name and the place where it was made.Stamped on the lid base of the handle, Penlon R [trademark] / Made in U K Printed on the blade base, MAC 3 RIESTER Printed on the blade base, STAINLESS STEEL C E / GERMANY Stamped on the blade base, TDD Stamped on the blade base, Gairway, laryngoscope, penlon, united kindom, germany, mac 3 reister, blade, the alfred hospital, melbourne, macintosh -
Geoffrey Kaye Museum of Anaesthetic History
Blade, Laryngoscope
Curved laryngoscope blade with light bulb only. Etched on the base of blade is engraved the word 'Whittam'. It has visible and deep scratches on top of its blade and back side. Also has on the edge of the blade a spot of oxidation and some green paint stains under the blade surface. Visible oxidation is present in the blade base back side over the small lamina attached by a screw. Engraved the presumably owner's name, Whittamlaryngoscope, blade, light bulb, curved laryngoscope, glass, whittam -
Geoffrey Kaye Museum of Anaesthetic History
Blade, Laryngoscope
Curved laryngoscope blade with light bulb only. It has visible scratches on top and back side of the blade. A rusty washer under the handle joint. Is also present in the blade base back side a curved shaped lamina attached by a screw. This blade correspond to a large size (adult) laryngoscope blade. It has stamped on the base inscriptions about: trade mark (PENLON), place where it was made (ENGLAND) and its material (Stainless).Stamped on the blade base, REGD. TRADE MARK / PENLON / MADE IN ENGLAND Stamped on the back edge of the blade, STAINLESSblade, penlon, light bulb, laryngoscope -
Geoffrey Kaye Museum of Anaesthetic History
Laryngoscope, MacIntosh, 1950
Object belonged to and was used by Dr Lennard Travers 1950-1970.Complete Macintosh laryngoscope piece with a curved medium sized attached blade with light bulb and a textured handle with serrated grip for easy of use and a screw in the blade connector. The handle is also a battery deposit to supply the led light bulb. The blade has general deep scratches on its surface and a slight metal deformation on top back of the blade. At the back of the blade is still attached the hinge that keeps in regular position the base and the blade, is also present a worn surface in this area. Green spots of dust and oxidation processes are present over the blade and the handle areas. A handle manufacturer stamp is located at the base of handle (see inscriptions for details).Stamped into base of handle: LONGWORTH INST. CO. / OXFORD / ENGLANDmacintosh, laryngoscope, blade, handle, longworth inst. co., england -
Geoffrey Kaye Museum of Anaesthetic History
Tongue Depressor, Boyle-Davis Gag
Chrome plated metal "L" shaped tongue depressor. The depressor arm downside has cross-hatched grooves to facilitate adherence to the tong. A small metal tube is attached to the upper-side of the depressor through which anaesthesia or oxygen could be administered. The lateral arm handle has grips engraved to attach the mouth gag frame which is missing. This item has a stamp inscription on its handle about maker's details, size and material. Black spots of dust are present inside the metal tube and out near the extreme of the tube. It has accumulated dust between the cross-hatched grooves. Minor scratches around the piece.Stamped in the depressor handle, D.H.A. / 6 / STAINLESSboyle-davis, tongue depressor, airway management -
Geoffrey Kaye Museum of Anaesthetic History
Blade, Laryngoscope, Macintosh, Circa 1943
"First described by professor R. R. Macintosh in the Lancet of February 13th, 1943, this design is now the acknowledged leader throughout the world." (PENLON, 1969) Reference: PENLON. 1969. Anaesthetic Equipment - Longworth Scientific Instrument Company LTD. Abingdon, Berkshire, England. January 1969. Macintosh semi curved blade designed in a child size, with a light bulb attached. Minor scratches and some slight hit marks over the piece surface caused by its previous use. It has stamped the manufacturer name and the place where it was made at the back of the blade.Stamped on the back blade base, Longworth / MADE IN ENGLANDmacintosh, blade, longworth, paediatrics, light bulb -
Geoffrey Kaye Museum of Anaesthetic History
Blade, Laryngoscope, Macintosh, circa 1943
"First described by professor R. R. Macintosh in the Lancet of February 13th, 1943, this design is now the acknowledged leader throughout the world." (PENLON, 1969) Reference: PENLON. 1969. Anaesthetic Equipment - Longworth Scientific Instrument Company LTD. Abingdon, Berkshire, England. January 1969.Macintosh semi curved blade designed in a child size, with a light bulb attached to the blade and a hinge attached to the back side of the base. Several scratches and deep hit marks over its surface caused by its previous use. This piece also has visible old dust spots and stains. Its contact stud is in a well condition and does not has any inscriptions. macintosh, blade, paediatrics, light bulb -
Geoffrey Kaye Museum of Anaesthetic History
Blade, Laryngoscope, Magill, circa 1943
Magill type blade to fit Longworth handles adult size without light bulb. Attached hinge at the back of the blade. Visible hit marks mostly present at the back top of the blade and below. Worn contact stud on base and lateral side at the light bulb connection. Dust spots around the piece. It has stamped on the blade base the attachment type name.Stamped at the attachment base of the blade in cursive writing, Longworthlongworth, magill, blade, adult blades, penlon -
Geoffrey Kaye Museum of Anaesthetic History
Tongue Depressor
J. Austen chrome plated tongue depressor blade only. Size 2 1/4, stainless steel material. The top arm of the instrument has a serrated grip below to facilitate tongue adherence, also has a middle space canal with semi circular welded rings to possibly introduce or attach an anaesthetic tube. This piece has in its internal lateral side engraved the possible owner's initial and last name. Minor scratches and dust marks are present over the piece as well as oxidation spots around engraved name. Weld spots in metallic semi circles edges on top of the piece.Engraved at the internal side of the handle, V. BRAND Stamped at the external side of the handle, J.AUSTEN / 2 1/4 / STAINLESStongue depressor, medical instruments, airway instruments, j. austen -
Geoffrey Kaye Museum of Anaesthetic History
Laryngoscope, Lynah, Circa 1915
Lynah's Ovoid Laryngeal Speculum with the light bulb and part of the connection wires still attached. Its semi square shape is characteristic of this kind of instrument, also has an screwable pointed end attachment. It has dusty and grey spots inside the canal of the blade near the light bulb canal. Solder spots are visible at the top of the blade as attachment of the laryngeal speculum blade base. General discolouration over the surface of this piece and hit marks present at the base of the handle. It was roughly engraved over the handle the owner’s details and year. Stamped at the base of the handle are the manufacturer’s details partially visible. Engraved at the handle, U N N A M E T . A D E L A I D E . c. 194[6] . Stamped at the base of the handle, [first line worn away might be MADE BY] / E / A D / [might be an S] YDN [might be an EY] / CHROME PLAT [incomplete word due stamp near the edge]laryngeal speculum, laryngeal instruments, unnamet, adelaide, lynah, henry lowndes -
Geoffrey Kaye Museum of Anaesthetic History
Laryngoscope, Shipway, c 1920
Shipway’s metallic medium size laryngoscope with bulbous curved handle. The section connecting the handle to the straight blade has a screw. Lateral orifice to attached light bulb connection which is not present on this item. The surface is very rusty and quite battered, presence of oxidation on its surface and discoloration of the metal. Has an inscription about the manufacturer.Stamped on its handle, MAYER & Co. LONDONshipway laryngoscope, laryngoscope, metal, mayer & co. london -
Geoffrey Kaye Museum of Anaesthetic History
Laryngoscope, Magill, 1926
Ivan Magill (1888-1986) designer, this piece was designed in 1926 along with other anaesthetic equipment.Chrome plated straight complete Magill laryngoscope in medium size format, with attached light bulb. Cylindrical handle for battery deposit and with a wavy hand grip for easy handling. Serrated and screwed lids on top and base of the handle grip for insertion of batteries and checking of electrical contact stud. The handle also has a metallic switch without any instruction of use. The arm of the handle has a detachable screw to adjust extendable blade position and firmness. The light bulb is attached to a metallic tube connector to the handle arm which is just pressed to the contact point base. The blade has a oxidation spot under the blade. The piece in full has several scratches marks mostly founded in handle, arm and top blade areas. Two stamped inscriptions are present on the arm area, the manufacturer name and register number.Stamped on the arm of the handle lateral side, A.CHARLES KING Stamped on the arm of the handle opposite lateral side, REG. NO. 74901[9]magill, a. charles king ltd, regi. no. 749019, switch, laryngoscope -
Geoffrey Kaye Museum of Anaesthetic History
Laryngoscope, Chevalier Jackson, Circa 1913
Please refer to The Wood Library for further information about this piece. URL: https://www.woodlibrarymuseum.org/museum/item/664/jackson-laryngoscope Chevalier Jackson direct laryngoscope, with attached small light bulb inside the internal blade. Brass coated piece with a large size. This piece has a discoloured and beaten surface with visible hit marks, deformation at the back of the blade and green spots in handle area. The hand anatomic handle is faceted and designed with a thumb rest section at the angle. Welding sections are visible along the blade base external canal and handle attachment area. No inscriptions.Anychevalier jackson, laryngoscope, light bulb, brass -
Geoffrey Kaye Museum of Anaesthetic History
Slide
Colour slide mounted in white slide case. Image depicts Clover Inhaler with cloth rebreather bag and leather facemask attachedHandwritten in pencil: EMBLEY'S / 9448 -
Geoffrey Kaye Museum of Anaesthetic History
Inhaler, Probyn Williams, c. 1900
In 1896 Robert James Probyn-Williams was appointed first honorary anaesthetist to the London Hospital and joined a select band of fulltime anaesthetists (26) in Great Britain. The Probyn Williams inhaler was a further modification of the Clover inhaler with narrow airways and rebreathing. The metal inhaler is ovoid shaped. The rotating gauge has a series of numbers engraved onto the inhaler for measurement. There is an elbow joint leading to a connector for attaching a re-breather bag, and at the other end is tap-style mechanism. There is a small glass bulb encased in a metal housing. The facemask is completely made of metal as well.Stamped into handle of tap: COEXTER & SONjoseph clover, frederick hewitt, robert probyn williams -
Geoffrey Kaye Museum of Anaesthetic History
Inhaler, Probyn Williams, Mayer & Meltzer, c. 1900
In 1896 Robert James Probyn-Williams was appointed first honorary anaesthetist to the London Hospital and joined a select band of fulltime anaesthetists (26) in Great Britain. The Probyn Williams inhaler was a further modification of the Clover inhaler with narrow airways and rebreathing.Ovoid shaped metal ether inhaler device with a dark brown leather fask mask attached.Moulded into inhaler: MAYER & MELTZER / LONDON -
Geoffrey Kaye Museum of Anaesthetic History
Accessory - Facemask
Pear shaped metal mask for attaching to Probyn Williams inhaler. The edge of the facemask is surrounded by a black leather cushion, with a tube on the top. The facemask is metal with a thumb action lever on connector.anaesthesia, inhalational, probyn williams, facemask -
Geoffrey Kaye Museum of Anaesthetic History
Instrument - Laryngoscope, Chevalier Jackson, Circa 1913
It is likely that this object belonged to Dr Giles.Chevalier Jackson medium size steel made laryngoscope. Hexagonal shape design on handle and arm blade with a thumb support at the handle angle, missing the bulb light and all the system to support it. Deep scratches over the top and under blade with presence of dust marks over the handle, arm and inside the blade canal. Also has a grey paint mark over the top blade area. No stamped inscriptions are present just a label attached with a possible owner's name and a reference code to the museum old catalog.Attached label hand written inscription, Giles / S 4. 13chavalier jackson, laryngoscope, stainless steel