Showing 6 items
matching complete laryngoscope
-
Geoffrey Kaye Museum of Anaesthetic History
Laryngoscope, MacIntosh
... complete laryngoscope...Complete Macintosh laryngoscope piece with a curved large... St Kilda Road Melbourne melbourne laryngoscope complete ...Complete Macintosh laryngoscope piece with a curved large sized attached blade with light bulb and a textured handle with serrated grip for easy of use and a screw in the blade connector. The handle is also a battery deposit to supply the led light bulb. The blade has general scratches on its surface because its use. At the back of the blade is still attached the curved lamina as holder of the base with the blade in its regular use position. Several engraved and stamped inscriptions are present all over the handle and blade (see inscriptions for details). Stamped on the base of the blade, BOC Stamped on the edge of the back side blade, STAINLESS Stamped on the back side blade base, MADE IN ENGLAND Engraved at the base of the blade attachment place, MAINLAND Engraved at the edge of the serrated grip of the handle, Alfred Anaes Stamped at the base of the handle, REGD TRADE MARK / P E N L O N / MADE IN ENGLAND Stamped at the bottom of the handle base, REGD TRADE MARK / P E N L O N / MADE IN ENGLAND Engraved at the bottom of the handle base, AnaeA / ALFREDlaryngoscope, complete laryngoscope, boc, penlon, handle, alfred hospital, anaesthesia -
Geoffrey Kaye Museum of Anaesthetic History
Laryngoscope, Flagg, circa 1915
... Complete laryngoscope used by Dr Lennard Travers. Medium... around 1915 and later used for 25 years. This laryngoscope blade ...Designed by Dr Paluel Flagg around 1915 and later used for 25 years. This laryngoscope blade was designed to meet certain expectations about laryngeal richness and to avoid major tracheal injuries in patients. (Ball, 2014) Article reference: C. M. Ball & R. N. Westhorpe. 2014. Anaesthesia & Intensive Care. Nov 2014, Vol. 42 Issue 6, p687-688. 2p.Complete laryngoscope used by Dr Lennard Travers. Medium sized Flagg straight blade with a slight curve at the distal end and a 'U' shape canal. The handle has a serrated grip for easy use and it is also a container for two batteries, it has a switch on its base. The full piece has visible and deep scratches over the top of blade around the stamped blade type inscription. The base of the blade has a worn surface with a slight discolouration due its use. No presence of led light bulb on blade. Minor scratches on handle base battery deposit with an ON - OFF switch black button. Stamped on blade, FLAGG LARYNGOSCOPE Stamped on top handle blade base, AUBURN, [W/A seal], N.Y.U.S.A. Stamped on the handle base power source button, ON [red colour], OFF [blue colour]flagg, laryngoscope, flagg blade, button, battery handle, straight blade -
Geoffrey Kaye Museum of Anaesthetic History
Laryngoscope, MacIntosh, 1950
... Complete Macintosh laryngoscope piece with a curved medium... to and was used by Dr Lennard Travers 1950-1970. macintosh laryngoscope ...Object belonged to and was used by Dr Lennard Travers 1950-1970.Complete Macintosh laryngoscope piece with a curved medium sized attached blade with light bulb and a textured handle with serrated grip for easy of use and a screw in the blade connector. The handle is also a battery deposit to supply the led light bulb. The blade has general deep scratches on its surface and a slight metal deformation on top back of the blade. At the back of the blade is still attached the hinge that keeps in regular position the base and the blade, is also present a worn surface in this area. Green spots of dust and oxidation processes are present over the blade and the handle areas. A handle manufacturer stamp is located at the base of handle (see inscriptions for details).Stamped into base of handle: LONGWORTH INST. CO. / OXFORD / ENGLANDmacintosh, laryngoscope, blade, handle, longworth inst. co., england -
Geoffrey Kaye Museum of Anaesthetic History
Laryngoscope, Magill, 1926
... Chrome plated straight complete Magill laryngoscope... switch laryngoscope Stamped on the arm of the handle lateral side ...Ivan Magill (1888-1986) designer, this piece was designed in 1926 along with other anaesthetic equipment.Chrome plated straight complete Magill laryngoscope in medium size format, with attached light bulb. Cylindrical handle for battery deposit and with a wavy hand grip for easy handling. Serrated and screwed lids on top and base of the handle grip for insertion of batteries and checking of electrical contact stud. The handle also has a metallic switch without any instruction of use. The arm of the handle has a detachable screw to adjust extendable blade position and firmness. The light bulb is attached to a metallic tube connector to the handle arm which is just pressed to the contact point base. The blade has a oxidation spot under the blade. The piece in full has several scratches marks mostly founded in handle, arm and top blade areas. Two stamped inscriptions are present on the arm area, the manufacturer name and register number.Stamped on the arm of the handle lateral side, A.CHARLES KING Stamped on the arm of the handle opposite lateral side, REG. NO. 74901[9]magill, a. charles king ltd, regi. no. 749019, switch, laryngoscope -
Geoffrey Kaye Museum of Anaesthetic History
Blade, Laryngoscope, Macintosh
Semi straight infant Macintosh blade with light bulb only. The item has a general good conservation and completeness regarding its hinge piece and base bulb connector. It has stamped the manufacturer name (PENLON) and the place where it was made (New Zealand).Stamped, REGD TRADE MARK / PENLON / MADE IN NEW ZEALANDpenlon, macintosh, straight laryngoscope, infant, blade, laryngoscope, new zealand -
Geoffrey Kaye Museum of Anaesthetic History
Laryngoscope, Macintosh
A laryngoscope is an instrument used to view the larynx (voice box), which is the opening to the trachea and lungs. It consists of a “blade,” which goes into the patient’s mouth, and a handle. Prior to 1943 when Macintosh introduced his curved blade, most laryngoscope blades were long and straight. The straight blades were used to directly hold the epiglottis. Macintosh’s curved blade works differently: it indirectly opens the epiglottis by applying pressure to a space between the root of the tongue and epiglottis, called the vallecula. The flange running along the left lower edge of Macintosh’s blade was also a novel innovation. It was designed to move the tongue to the side, which improved the view of the larynx and made more room for a breathing tube. The Macintosh Laryngoscope remains one of the most popular blades worldwide. (Source: Wood Library Museum) This laryngoscope was previously owned by John Mainland, as evidenced by the name etched into the handle. Mainland graduated from the University of Melbourne in 1950 with a Bachelor of Science degree. After researching and completing his medical degree, Mainland entered into the field of anaesthetics, training at the Royal Women's and Royal Children's Hospitals, later Alfred Hospital, in 1959. He completed training in 1964 and remained at the Alfred Hospital. During his career, he also became the first anaesthetist appointed to the position of Professor in Victoria. His other achievements include manufacturing a respiratory monitoring module that accompanied astronauts on the United States moon landing and developing a stimulator to lessen the risk of deep vein thrombosis in surgical patients. Mainland became a Fellow of the Australian and New Zealand College of Anaesthetists in 1992, retiring from the profession in 1997.Oblong shaped handle with textured grip. Attached is a laryngoscope blade in a cruved shaped with light tube running through one side.Etched into top of handle: J.F. MAINLAND •Stamped into top of handle: REGD TRADE MARK / PENLON / MADE IN ENGLAND •Stamped into base of handle: CLOSE [arrow] •Etched into base of blade: MAC / 4 •Stamped into side of blade: REGD TRADE MARK / PENLON / MADE IN ENGLAND •Stamped into side of blade: STAINLESSmacintosh, robert reynolds, new zealand, laryngoscope, mainland, john, alfred hospital, moon landing