Showing 9 items
matching endotracheal intubation
-
Geoffrey Kaye Museum of Anaesthetic History
Tube, Endotracheal, Cuffed, A Charles King Ltd. England
... for use in oral endotracheal intubation.... intubation. Tube, Endotracheal, Cuffed A Charles King Ltd. England ...Set of brown and orange cuffed rubber tubes with an second, finer, rubber tube extending from the cuff. The tubes are all for use in oral endotracheal intubation.Versions of the following are printed in black ink on each of the tubes: [size] MEDICAL AND INDUSTRIAL EQUIPMENT MAGILL'S TUBE / MADE IN ENGLAND or; [size] ORAL Medishield / MAGILL / CUFFED / MADE IN UNITED KINGDOMmagill, ivan, endotracheal, intubation, oral, cuffed, tube -
Geoffrey Kaye Museum of Anaesthetic History
Tube, Endotracheal, Uncuffed, A. Charles King Ltd, c.1932
... for nasal endotracheal intubation.... the patient's nose. magill endotracheal intubation nasal a. charles king ...This is an early example of an endotracheal tube (c.1932) invented by Ivan Magill. The shattered faces and jaws of wounded soldiers presented real difficulties for the administration of anaesthesia. Ivan Magill and Stanley Rowbotham developed endotracheal tubes for these procedures that were more efficient and practical than the earlier insufflation catheters.The attached safety pin was used to prevent the loss of the tube down the patient's nose. Orange/brown rubber tubing with a bevelled edge at one end a safety pin stuck through the other end. This tube was used for nasal endotracheal intubation.Printed in black ink on tube: NO. 5 NASAL A. CHARLES KING LTD. MAGILL'S TUBE 27 / BRITISH MADEmagill, endotracheal, intubation, nasal, a. charles king ltd, england -
Geoffrey Kaye Museum of Anaesthetic History
Tube, Endotracheal, Uncuffed Rubber Nasal Tube
... and a bevelled edge at the other for nasal endotracheal intubation... the patient's nose. Magill, Ivan Endotracheal Intubation Nasal Airway ...This is an early example of an endotracheal tube invented by Ivan Magill. The shattered faces and jaws of wounded soldiers presented real difficulties for the administration of anaesthesia. Ivan Magill and Stanley Rowbotham developed endotracheal tubes for these procedures that were more efficient and practical than the earlier insufflation catheters.The attached safety pin was used to prevent the loss of the tube down the patient's nose.Brown rubber tubing with three pairs of holes at one end and a bevelled edge at the other for nasal endotracheal intubation. There is a large safety pin stuck through the first pair of holes.magill, ivan, endotracheal, intubation, nasal, airway -
Geoffrey Kaye Museum of Anaesthetic History
Tube, Endotracheal, Kuhn, Circa 1900
... The evolution of endotracheal intubation for anaesthesia... of endotracheal intubation for anaesthesia was a slow process. Franz Kuhn ...The evolution of endotracheal intubation for anaesthesia was a slow process. Franz Kuhn (1806-1929), a head and neck surgeon working in Kassel, Germany, between 1902 and 1911, is said to have done more than any other to obtain general recognition for endotracheal anaesthesia. Kuhn's tube, is a flexible metal one inserted on a stilette which was then withdrawn. The tube was then secured with an elastic neck strap and connected by a rubber tube to a Trendelenburg cone. The glottis was packed with oiled gauze. Metal spiral tube with elaborate handle at one end and rounded at the other. There is a metal clasp at the base of the handle which all forms part of the endotracheal tube. Inside the tube is a curved metal piece that functions as an introducer.kuhn, endotracheal, airway, intubation -
Geoffrey Kaye Museum of Anaesthetic History
Laryngeal Mask Airway, Mallinckrodt
... endotracheal intubation..., archive england mallinckrodt laryngoseal endotracheal intubation ...Blue transparent plastic tubing with a clear plastic laryngeal mask attached. There is an additional fine tube threaded through the blue tubing toward the mask opening.Printed in black ink on blue plastic tube: SIZE / 2.5 / MALLINCKRODT LaryngoSeal TM / Single Use Only 20 - 30kglaryngeal mask airway, brain, archive, england, mallinckrodt, laryngoseal, endotracheal intubation -
Geoffrey Kaye Museum of Anaesthetic History
Laryngeal Mask Airway, Intavent
... endotracheal intubation... brain, archie endotracheal intubation autoclavable Printed ...The Laryngeal Mask Airway was invented in 1983 by British anaesthetist, Archie Brain.Yellow plastic tubing with a pink rubber laryngeal mask attached. There is an additional fine yellow tube threaded through the base of the rubber mask. Printed in black in along side: #4 LARYNGEAL MASK AUTOCLAVABLE INTAVENT 3:1laryngeal, brain, archie, endotracheal intubation, autoclavable -
Geoffrey Kaye Museum of Anaesthetic History
Tube, Endotracheal, Double Lumen, Mallinckrodt
... or the left lung. Endotracheal Intubation Double Lumen Mallinckrodt ...This is an unused example of a Double Lumen Endotracheal Tube. This tube would be used to achieve the selective one sided ventilation of either the right or the left lung. Clear plastic tube with a "v" shaped connector at one end that holds two tubes, one blue one and one clear plastic. There are two finer plastic tubes on either side of the central tube, one blue one and one clear plastic. Blue plastic cuff and a clear plastic cuff are wrapped around the tube at the other end.Printed in black ink on the side of the central tube: Mallinckrodt R 35Fr. LEFT Brocho-Cath TM 27 Do Not Reuse 29 31cm Printed in black ink on blue plastic tube: BRONCHIAL Printed in black ink on clear plastic tube: 35Fr. TRACHEALendotracheal, intubation, double lumen, mallinckrodt, magill, united states of america -
Geoffrey Kaye Museum of Anaesthetic History
Tube, Endotracheal, Double Lumen, Mallinckrodt
... . Endotracheal Magill Intubation Mallinckrodt United States of America ...This is an example of a Double Lumen Endotracheal Tube. This tube is used to achieve the selective one sided ventilation of either the right or the left lung.Clear plastic tube with a "v" shaped connector at one end that holds two tubes, one blue one and one clear plastic. There are two finer plastic tubes on either side of the central tube, one blue one and one clear plastic. Blue plastic cuff and a clear plastic cuff are wrapped around the tube at the other end.Printed in black ink on the side of the central tube: Mallinckrodt R 41Fr. RIGHT Brocho-Cath TM 27 Do Not Reuse 29 I.T. 31cm Printed in black ink on blue plastic tube: BRONCHIAL Printed in black ink on clear plastic tube: 41Fr. TRACHEALendotracheal, magill, intubation, mallinckrodt, united states of america, airway -
Geoffrey Kaye Museum of Anaesthetic History
Archie Brain laryngeal mask and airway, Dr Archie Brain, circa 1982
... ) as an alternative to endotracheal intubation. Since first gaining a patent... innovation and provides an alternative to endotracheal intubation ...Taking castings from the larynx of cadaver's, Archie Brain studied the anatomy and physiology of the upper airway in minute detail. He devised the Laryngeal Airway Marsk (LMA) as an alternative to endotracheal intubation. Since first gaining a patent in 1982, he produced over 1000 prototypes over the next 30 years in a constant effort to improve the device and patient safety. The LMA is a recent innovation and provides an alternative to endotracheal intubation and has made a significant contribution to safe airway management. Ovoid shaped black rubber layrngeal airway with orange access point stopper. Translucent rubber tube is glued into the airway and is cutaway within the internal space of the airway. The item is a prototype and the materials used to construct it are gathered from different medical items. The following text is present on the rubber tubing: 'EX 9.5 ORAL 12.9 USE ONCE Z79-IT 24 26 29'.anaesthesia, dr archie brain, laryngeal, mask, airway, medical advances, rubber, prototype, endotracheal