Showing 11 items
matching portable regulating ether inhaler
-
Geoffrey Kaye Museum of Anaesthetic History
Inhaler, Clover (modified), Allan & Hanbury
... Portable regulating ether inhaler... described his Portable Regulating Ether Inhaler on Jan. 20, 1877... as the beginning of WWII Joseph Clover Portable regulating ether inhaler ...Dr. Joseph Clover (1825-1882), an English physician, first described his Portable Regulating Ether Inhaler on Jan. 20, 1877. Clover was an especially sought after anesthesiologist and early pioneer in the specialty. This was the best-known of many inhalers that Clover designed. The dome-shaped reservoir was turned to points on a control dial to gradually increase or decrease the percentage of the air that passed over the ether. Several inventors based new inhalers on this, while the original continued to be manufactured as late as the beginning of WWIIMetal based inhaler with glass dome lid. From the glass dome an elbow joint leads to a bulb for a rebreather bag [no bag]. There is a cork sealing an opening at the rear of the metal base and a blue sticker adhered.Printed in white on blue sticker: O.2.10 Manufacturer's logo moulded into metal insertjoseph clover, portable regulating ether inhaler -
Geoffrey Kaye Museum of Anaesthetic History
Inhaler, Clover, c. 1877
... Portable regulating ether inhaler... described his Portable Regulating Ether Inhaler on Jan. 20, 1877... as the beginning of WWII. Joseph Clover Portable regulating ether inhaler ...Dr. Joseph Clover (1825-1882), an English physician, first described his Portable Regulating Ether Inhaler on Jan. 20, 1877. Clover was an especially sought after anesthesiologist and early pioneer in the specialty. This was the best-known of many inhalers that Clover designed. The dome-shaped reservoir was turned to points on a control dial to gradually increase or decrease the percentage of the air that passed over the ether. Several inventors based new inhalers on this, while the original continued to be manufactured as late as the beginning of WWII.Metal domed chamber with a bulb attachment on an elbow joint for rebreather bag. There is also a connector for a facemask, but no facemask.White printing on blue sticker: O.2.2. •Engraved on dome: Clover's Inhaler / 1877.joseph clover, portable regulating ether inhaler -
Geoffrey Kaye Museum of Anaesthetic History
Clover's modified ether inhaler, Coexeter, London, 1876
... later, portable regulating ether inhaler.... this modified version over his later, portable regulating ether inhaler ...This is a modified version of the original Clover inhaler. Joseph Thomas Clover preferred this modified version over his later, portable regulating ether inhaler.This modified Clover's ether and chloroform inhaler is composed of metal and is cylindrical in shape. There is a gas distribution control key on the top and a metal hook enables the operator to hang the vaporiser from a strap around his/her neck. Stamped on top tap: COEXETER LONDONjoseph thomas clover, inhaler, ether, anaesthetic, portable, nitrous oxide, modified, gas, coexeter london, chloroform, rebreather bag, face mask -
Geoffrey Kaye Museum of Anaesthetic History
Equipment - Inhaler, Clover, Mayer & Meltzer
... described his Portable Regulating Ether Inhaler on Jan. 20, 1877... Regulating Ether Inhaler on Jan. 20, 1877. Clover was an especially ...Dr. Joseph Clover (1825-1882), an English physician, first described his Portable Regulating Ether Inhaler on Jan. 20, 1877. Clover was an especially sought after anesthesiologist and early pioneer in the specialty. This was the best-known of many inhalers that Clover designed. The dome-shaped reservoir was turned to points on a control dial to gradually increase or decrease the percentage of the air that passed over the ether. Several inventors based new inhalers on this, while the original continued to be manufactured as late as the beginning of WWII. Dome shaped metal chamber with a red leather face mask attached at one end and a metal elbow joint at the other, including a bulb for a rebreather bag and a tap mechanism.Engraved on dome of chamber: Mayer & Meltzer / London / Clover's Inhaler •Stamped on flat base of chamber: 1 2 3 1 2 3joseph clover, portable, inhaler -
Geoffrey Kaye Museum of Anaesthetic History
Inhaler, Clover (modified), Mayer & Co. London, c. 1906
... described his Portable Regulating Ether Inhaler on Jan. 20, 1877... Regulating Ether Inhaler on Jan. 20, 1877. Clover was an especially ...Dr. Joseph Clover (1825-1882), an English physician, first described his Portable Regulating Ether Inhaler on Jan. 20, 1877. Clover was an especially sought after anesthesiologist and early pioneer in the specialty. This was the best-known of many inhalers that Clover designed. The dome-shaped reservoir was turned to points on a control dial to gradually increase or decrease the percentage of the air that passed over the ether. Several inventors based new inhalers on this, while the original continued to be manufactured as late as the beginning of WWII.Metal dome chamber with flat base and two circular pains of glass on each side of the dome as viewing holes. There is a long connector tube with an elbow joint attached to a bulb for a rebreather bag. A previous exhibition label, typed in black ink on buff coloured card, has been tied to the connector.Moulded into the connector for the rebreather bag: MAYER & MELTZER No 212827 •Printed in white on blue sticker: O.2.9. •Stamped into dome: MAYER & MELTZER / LONDON •Typed onto exhibition label: MODIFIED CLOVER'S INHALER. / c.1906. / Name unknown. the modification consists / in windows to shew the ether-level in the / bowl. The inhaler has otherwise the same / restricted channels as the model of 1877 / and shares its faults. / (Gift of Dr. A.E. Rowden White, 1939).joseph clover, wilson smith -
Geoffrey Kaye Museum of Anaesthetic History
Inhaler, Clover, Mayer & Meltzer
... described his Portable Regulating Ether Inhaler on Jan. 20, 1877... Regulating Ether Inhaler on Jan. 20, 1877. Clover was an especially ...Dr. Joseph Clover (1825-1882), an English physician, first described his Portable Regulating Ether Inhaler on Jan. 20, 1877. Clover was an especially sought after anesthesiologist and early pioneer in the specialty. This was the best-known of many inhalers that Clover designed. The dome-shaped reservoir was turned to points on a control dial to gradually increase or decrease the percentage of the air that passed over the ether. Several inventors based new inhalers on this, while the original continued to be manufactured as late as the beginning of WWII.Metal domed chamber with a bulb attachment on an elbow joint for rebreather bag. There is also a connector for a facemask, but no facemask.Engraved on dome of chamber: Clover's Inhaler / Mayer & Meltzer / London •Moulded in to metal at connector: MAYER & MELTZER RD. NO. 212327joseph clover, closed administration, mayer & meltzer -
Geoffrey Kaye Museum of Anaesthetic History
Inhaler, Clover, Mayer & Meltzer
... described his Portable Regulating Ether Inhaler on Jan. 20, 1877... Regulating Ether Inhaler on Jan. 20, 1877. Clover was an especially ...Dr. Joseph Clover (1825-1882), an English physician, first described his Portable Regulating Ether Inhaler on Jan. 20, 1877. Clover was an especially sought after anesthesiologist and early pioneer in the specialty. This was the best-known of many inhalers that Clover designed. The dome-shaped reservoir was turned to points on a control dial to gradually increase or decrease the percentage of the air that passed over the ether. Several inventors based new inhalers on this, while the original continued to be manufactured as late as the beginning of WWII.Metal dome shaped chamber with an elbow joint for attaching a rebreather. A cotton rebreather bag is attached.Engraved on dome: Mayer & Meltzer / London / Clover's Inhalerjoseph clover, edward henry embley, closed administration, rebreather -
Geoffrey Kaye Museum of Anaesthetic History
Inhaler, Clover, Mayer & Meltzer, 1877
... described his Portable Regulating Ether Inhaler on Jan. 20, 1877... Regulating Ether Inhaler on Jan. 20, 1877. Clover was an especially ...Dr. Joseph Clover (1825-1882), an English physician, first described his Portable Regulating Ether Inhaler on Jan. 20, 1877. Clover was an especially sought after anesthesiologist and early pioneer in the specialty. This was the best-known of many inhalers that Clover designed. The dome-shaped reservoir was turned to points on a control dial to gradually increase or decrease the percentage of the air that passed over the ether. Several inventors based new inhalers on this, while the original continued to be manufactured as late as the beginning of WWII. (Source: Wood Library Museum)Black round topped box with brass hooks at front and brass hinges at rear. There is a black fabric handle on the top. Inside the box is black padding with the manufacturer's logo printed in gold leaf. There is a square section in the base of the box for holding the square clear glass bottle for ether. There is also a dome-shaped metal inhaler with a "whistle tip" type connection to the mask. The mask is made of tan leather. There is also a metal ether measure for pouring the ether.Printed in gold leaf inside lid of box: MAYER & MELTZER [?] PORTLAND ST. / MAKERS •Engraved on side of inhaler: Mayer & Meltzer / London •Stamped on connector of inhaler: MAYER & MELTZER RN NO 212327 •Engraved on rear of inhaler: Clover's Inhaler •Printed in white on blue sticker: O.2.5A •Measurements have been stamped on the bottom of the inhaler. •Printed in black ink on mask: MADE IN ENGLAND •Stamped on metal connector inside mask: 6 •Printed in black ink on white manufacturer's label on glass bottle: ETHER PURUS '720 / H. Francis & Co., Melbourne.clover, joseph, mollison, crawford henry, george bankin, mccaul, kevin, royal women's hospital, coroner, freemason, surgeon, gynaecologist, obstetrician, mayer & meltzer, francis & co, melbourne, ether purus -
Geoffrey Kaye Museum of Anaesthetic History
Inhaler, Clover (sectioned)
... described his Portable Regulating Ether Inhaler on Jan. 20, 1877... Regulating Ether Inhaler on Jan. 20, 1877. Clover was an especially ...Dr. Joseph Clover (1825-1882), an English physician, first described his Portable Regulating Ether Inhaler on Jan. 20, 1877. Clover was an especially sought after anesthesiologist and early pioneer in the specialty. This was the best-known of many inhalers that Clover designed. The dome-shaped reservoir was turned to points on a control dial to gradually increase or decrease the percentage of the air that passed over the ether. Several inventors based new inhalers on this, while the original continued to be manufactured as late as the beginning of WWII. Dr Geoffrey Kaye sectioned equipment, enabling medical students to see the inner workings and gain insight into the engineering of the equipment.Cross section of Clover's inhaler attached to a circular metal base.Handwritten on white sticker at rear: P / 26 / B •White print on blue sticker: O.2.3. •Engraved on dome side of inhaler: G. Kaye sect. 1939.joseph clover, geoffrey kaye -
Geoffrey Kaye Museum of Anaesthetic History
Inhaler, Clover (modified)
... described his Portable Regulating Ether Inhaler on Jan. 20, 1877... Regulating Ether Inhaler on Jan. 20, 1877. Clover was an especially ...Dr. Joseph Clover (1825-1882), an English physician, first described his Portable Regulating Ether Inhaler on Jan. 20, 1877. Clover was an especially sought after anesthesiologist and early pioneer in the specialty. This was the best-known of many inhalers that Clover designed. The dome-shaped reservoir was turned to points on a control dial to gradually increase or decrease the percentage of the air that passed over the ether. Several inventors based new inhalers on this, while the original continued to be manufactured as late as the beginning of WWII. This modified version differs from the original Clover inhaler as it has a glass dome chamber at the top allowing the level of ether to be monitored.Metal based chamber with glass dome top. There is a metal connection point at the top of the glass dome for a rebreather bag, with a whistle tip connection point at the base of the chamber for a facemask. There is no rebreather bag or facemask. There is a black plastic stopper to the side of the chamber, with a glass bulb with a metal wire cage covering.joseph clover, lambert buck, closed administration -
Geoffrey Kaye Museum of Anaesthetic History
Inhaler, Clover, The Holborn Surgical Instrument Company, 1877
... described his Portable Regulating Ether Inhaler on Jan. 20, 1877... Regulating Ether Inhaler on Jan. 20, 1877. Clover was an especially ...Dr. Joseph Clover (1825-1882), an English physician, first described his Portable Regulating Ether Inhaler on Jan. 20, 1877. Clover was an especially sought after anesthesiologist and early pioneer in the specialty. This was the best-known of many inhalers that Clover designed. The dome-shaped reservoir was turned to points on a control dial to gradually increase or decrease the percentage of the air that passed over the ether. Several inventors based new inhalers on this, while the original continued to be manufactured as late as the beginning of WWII. Clover, to spare the patient the unpleasantness of induction with his "closed" inhaler (1877), suggested the "mitigated-ether" technique. The inhaler was fitted with a bypass tap for the reception of N2O. The bag was filled with the gas and anaesthesia was inducted a combination of N2O and asphyxiation. Ether was then admitted gradually by rotation of the bowl of the inhaler. When the patient had been duly "weaned over" to ether, the mask was lifted, the N2O allowed to escape, the bag refilled with exhaled air, and normal anaesthesia "a la Clover's inhaler" was continued.Metal domed chamber with a bulb attachment for rebreather bag, including a tap mechanism. Remnants of the paper rebreather bag are attached to the bulb. At the other end is a yellow facemask made of plastic (probably celluloid). The manufacturer's logo has been moulded into the dome of the chamber.Manufacturer's logo: THE HOLBORN / SURGICAL INSTRUMENT CO. LTD. / LONDON •Blue sticker with white writing: O.2.4.joseph clover, mitigated-ether, nitrous oxide, n2o, closed method