Geoffrey Kaye Museum of Anaesthetic History
Photograph
... St Kilda Road Melbourne melbourne Ether vaporiser Anaesthetic ...Black and white photograph of a drawing of anaesthetic equipment, a flowmeter and an ether vaporiser. On the right is the ether vaporiser inside a glass cylinder, with a control tap on top of it. It is attached to a metal cylinder which houses the flowmeter which is measuring the Oxygen and Nitrous Oxide. There is a round Oxygen control and a Nitrous Oxide control attached underneath the metal cylinder, as well as an Oxygen Bypass and a Nitrous Oxide Bypass. The diagram has each part of the apparatus named with an arrow pointing to the parts.ether vaporiser, anaesthetic equipment, flowmeter, nitrous oxide, oxygen -
Geoffrey Kaye Museum of Anaesthetic History
Photograph
Black and white photograph of anaesthetic apparatus inside a portable case which is standing upright and open. Inside the right half of the case is a flowmeter connected to several rubber tubes and a small Vinyl Ether vaporiser with a lever switched to OFF. The left half of the case has four shelves with equipment on each shelf. The top shelf has an oropharyngeal airway tube. The second shelf has two metal facemask inhalers. The third and fourth shelves hold metal cylindrical inhalers. The photograph shows the letters A - J with arrows, pointing to the different parts of the equipment.anaesthetic equipment, portable case, flowmeter, inhaler -
Geoffrey Kaye Museum of Anaesthetic History
Photograph
Black and white photograph of anaesthetic apparatus inside a portable case which is standing upright and open. Inside the right half of the case is a flowmeter connected to several rubber tubes and a small Vinyl Ether vaporiser with a lever switched to ON. The left half of the case has four shelves with equipment on each shelf. The top shelf has an oropharyngeal airway tube. The second shelf has a metal facemask inhaler and a glass vaporiser. The third and fourth shelves hold metal cylindrical inhalers. In front of the case is a metal inhaler with face mask, attached to a rebreathing bag.Handwritten in grey pencil on reverse: Fig 17 new bookanaesthetic equipment, portable case, flowmeter, inhaler, vinyl ether -
Geoffrey Kaye Museum of Anaesthetic History
Photograph
Black and white photograph of the head of a portable Foregger "Metric" Gas Anaesthesia Apparatus. The apparatus has glass flowmeters and controls for fine and coarse oxygen, cyclopropane, nitrous oxide and carbon dioxide. There is also an ether container and a blood pressure nanometer.•Handwritten in grey pencil on reverse: Dr. Desai's Special Metric •Handwritten in black ink on reverse: III. •Handwritten in grey pencil on reverse: dvpd.anaesthetic equipment, anaesthetic machine, flowmeter, foregger metric gas anaesthesia apparatus, oxygen, nitrous oxide, carbon dioxide, cyclopropane -
Geoffrey Kaye Museum of Anaesthetic History
Photograph
... Geoffrey Kaye Museum of Anaesthetic History ANZCA House 630 ...The Lidwill machine was designed by Mark Lidwill in 1913, for the purpose of mechanical or insufflation anaesthesia. It was manufactured by Elliott Bros. of Sydney.Colour photograph of a Lidwill anaesthetic machine sitting on carpet. A circular metal ether vaporiser sits on a brown wooden base, with brown tubes connecting to a trap bottle and metal valves, and a brown tube connected to the valve is coiled on the floor.anaesthetic equipment, lidwill anaesthetic machine, mark lidwill, ether vaporiser, elliott bros sydney -
Geoffrey Kaye Museum of Anaesthetic History
Photograph
The Bruck Inhaler is a modification of the Clover Inhaler, designed by Lambert Bruck.Colour photograph of a Bruck inhaler lying on its side on a wooden table. The metal inhaler is oval shaped with one half made of glass, and also has a vertical crosspiece. Lying next to the inhaler is a face mask and a filler for measuring ether.anaesthetic equipment, bruck inhaler, ludwig bruck, inhaler, clover inhaler -
Geoffrey Kaye Museum of Anaesthetic History
Photograph
... Lidwill anaesthetic machine Mark Lidwill Ether vaporiser ...The Lidwill machine was designed by Mark Lidwill in 1913, for the purpose of mechanical or insufflation anaesthesia. It was manufactured by Elliott Bros. of Sydney. Shortly afterwards, the Anaesthetic and Portable Machine Company of Sydney devised a machine that was functionally the same but also contained an electric lamp heater.Colour photograph of a modified Lidwill anaesthetic machine sitting on carpet, taken from above. The vaporiser is metal and circular, and has metal valves and controls and two orange tubes. The machine has an electric cord and power plug which is coiled on the floor.anaesthetic equipment, lidwill anaesthetic machine, mark lidwill, ether vaporiser, anaesthetic and portable machine company of sydney, vaporiser -
Geoffrey Kaye Museum of Anaesthetic History
Equipment - Junker's apparatus
Between 1867 and 1920, anaesthesia for dental operations was often maintained by blowing the vapour of ether or chloroform into the patients' oral or nasal pharynx. Junker's inhalers are a "blow over" device used with a hand-held bellows to bubble air through liquid chloroform and to the patient. It was initially intended for use with bichloride of methylene, a mixture of chloroform and methyl alcohol. Ferdinand Ethelbert Junker introduced his inhaler in 1867 as appointed physician to Samaritan Free Hospital for Women (although it didn't have that name until c.1904). Glass jar with liquid measure markers etched onto. The jar has a metal lid, with a metal tube descending into the jar. Two metal tubes are protuding out of the top of the lid, and each has a small section of rubber tubing attached. There is also a metal hook, used to attached the jar to the physicians (anaesthetist's) lapel.Stamped into frame of metal lid: LONDON MADEjunker, blow over, chloroform, samaritan free hospital for women -
Geoffrey Kaye Museum of Anaesthetic History
Photo album, Anaesthetic trays, 1950s - 1970s
The photo contains a series of photographs depicting the correct procedure for setting up an anaesthetic tray for theatre.Green, leather bound photo album with brown leather edge, held together by brown and gold yarn. There is gold gilt lettering on the front, surrounded by a gold gilt decorative oval, spelling out "Photographs". Inside the album are a series of heavy paper pages with photographs and labels stuck on to them. Not all pages have been used, and additional photographs were stored among the blank pages. These have now been relocated to BK3. The photos depict the various ways in which an anaesthetic tray should be prepared for particular types of operations.White sticker [discoloured] adhered to top right hand corner of photo album, with handwritten inscription: ANAESTHETIC TRAYSanaesthesia, anesthesia, surgery, boyle's machine, trilene, ether, laryngoscope, endotracheal tubing -
Geoffrey Kaye Museum of Anaesthetic History
Equipment - Ether dropper
"Y" shaped hollow metal tubing with a red rubber stopper at the intersection of the "Y". -
Geoffrey Kaye Museum of Anaesthetic History
Equipment - Bellamy Gardner mask, 1908
H. Bellamy Gardner, an anaesthetist at the Charing Cross Hospital, was the first to use open ether in England and was responsible for popularizing the technique. Bellamy Gardner's mask consists of a wire frame which was covered with layers of gauze. He recommended constructing a face-pad consisting of several layers of gauze which were rolled together and tied to make an oval. This was applied to the face and the mask rested on the top. Ether was then administered directly on to the mask.Oval chrome-plated steel wire frame designed to fit around a face. The wire-framed dome has both vertical and horizontal wire components to sit over a patient's nose and mouth. Ether was applied to a gauze pad which was held securely in place by a hinged wire lid. This is a modified version of Bellamy Gardner's original mask.Etched on clasp: BELLAMY / GARDNER'S / ETHER MASKether, gauze -
Geoffrey Kaye Museum of Anaesthetic History
Book - Case book: Joseph Clover, Medical Observations J.T. Clover, 1846
Dr Joseph Clover was an early pioneer of anaesthesia, particularly chloroform. Like most physicians, he recorded his work in a casebook. This casebook records Clover's first administration of ether as anaesthesia. The book was given to Professor Robert Mackintosh by Mary Clover, Joseph Clover's daughter. along with other casebooks. Mackintosh then proceeded to re-gift the casebooks and they are now dispersed. Clover wrote this casebook when he was a medical student, before he trained as a surgeon and around the time that anaesthesia was discovered. He eventually became the most important authority on anaesthesia in Britain and is featured on the crest of the Royal College of Anaesthetists. This artefact associated with one of the world's foremost pioneers of anaesthesia is historically and scientifically significant on an international level, and is significant for its rarity, condition and research potential. It is one of the most significant items in the Collection.Bound book with heavy marbled card cover with red leather binding strip along the spine. Insides leaves have handwritten text by Joseph Clover recording his work.joseph clover, robert mackintosh, mary clover, anaesthesia