Showing 4377 items
matching road metal
-
Geoffrey Kaye Museum of Anaesthetic History
Needles
Metal tin with hinged side and allocated space for twelve (12) needles with only five (5) needles present.Stamped into flat of connector: ACIDEX / 17hypodermic, needle, syringe, acidex, germany -
Geoffrey Kaye Museum of Anaesthetic History
Needles
Brown and white cardboard box with white manufacturer's label adhered to the front. The box contains clear plastic tubes, holding two (2) metal needles in each tube. There is allocation for six (6) needles in the tubing, but only four (4) needles are present. There is allocation for another tubing section, but that is not present.Stamped into flat portion of connector: YALE / RUSTLESS / B-D / 25hypodermic, needle, syringe, yale, regular point, b-d lok, becton, dickinson & co, rutherford -
Geoffrey Kaye Museum of Anaesthetic History
Needles
Cream coloured metal tin with hinged side and manufacturer's information in red and black printed text on front of tin. Inside tin are twelve (12) needles on a metal tray which is wrapped and sealed with a plastic covering.hypodermic, needle, syringe, unimed, switzerland -
Geoffrey Kaye Museum of Anaesthetic History
Needle
Cream coloured metal tin with hinged side and manufacturer's information in red and black printed text on front of tin. Inside tin are twelve (12) needles on a metal tray which is wrapped and sealed with a plastic covering.hypodermic, needle, syringe, unimed, switzerland -
Geoffrey Kaye Museum of Anaesthetic History
Laryngoscope
Metal laryngoscope in two parts. A round hollow handle with a textured grip and a screwed in base for holding batteries. The metal blade screws in to the handle and has a moulded section for a small light bulb. Engraved in to top of blade, D.A. Engraved in to base of handle, B.T.S. / R.W.H. D.A. Stamped in top of the handle, PAT.NO.683731 Stamped in top of the handle, BRITISH [indecipherable]laryngoscope, light bulb, battery -
Geoffrey Kaye Museum of Anaesthetic History
Blade, Laryngoscope, Magill
Magill straight laryngoscope blade with tubular space for a light bulb connection (no light bulb is present). It is a PENLON piece, made in England. Size 1, for infant use. Has a slight yellowish discolouration over its base. General scratches around the base of the blade and a sticky old mark bellow an engraved inscription. It has engraved the name of the hospital where it came from and the initials of its owner.Engraved under the blade arm base the name, Royal Childrens Hospital Engraved in its lateral side attachment base piece the initials, D. A. Stamped at the back of the attachment base piece the type and size, MAGILL / 1 Stamped in its lateral side attachment base piece the trademark name and its made place, REG [is not visible the continuation] / PENLON / MADE IN ENGLANDmagill, blade, royal childrens hospital, metal, d.a. -
Geoffrey Kaye Museum of Anaesthetic History
Laryngoscope, MacIntosh, 1950
Object belonged to and was used by Dr Lennard Travers 1950-1970.Complete Macintosh laryngoscope piece with a curved medium sized attached blade with light bulb and a textured handle with serrated grip for easy of use and a screw in the blade connector. The handle is also a battery deposit to supply the led light bulb. The blade has general deep scratches on its surface and a slight metal deformation on top back of the blade. At the back of the blade is still attached the hinge that keeps in regular position the base and the blade, is also present a worn surface in this area. Green spots of dust and oxidation processes are present over the blade and the handle areas. A handle manufacturer stamp is located at the base of handle (see inscriptions for details).Stamped into base of handle: LONGWORTH INST. CO. / OXFORD / ENGLANDmacintosh, laryngoscope, blade, handle, longworth inst. co., england -
Geoffrey Kaye Museum of Anaesthetic History
Tongue Depressor, Boyle-Davis Gag
Chrome plated metal "L" shaped tongue depressor. The depressor arm downside has cross-hatched grooves to facilitate adherence to the tong. A small metal tube is attached to the upper-side of the depressor through which anaesthesia or oxygen could be administered. The lateral arm handle has grips engraved to attach the mouth gag frame which is missing. This item has a stamp inscription on its handle about maker's details, size and material. Black spots of dust are present inside the metal tube and out near the extreme of the tube. It has accumulated dust between the cross-hatched grooves. Minor scratches around the piece.Stamped in the depressor handle, D.H.A. / 6 / STAINLESSboyle-davis, tongue depressor, airway management -
Geoffrey Kaye Museum of Anaesthetic History
Blade, Laryngoscope, Macintosh, Circa 1943
"First described by professor R. R. Macintosh in the Lancet of February 13th, 1943, this design is now the acknowledged leader throughout the world." (PENLON, 1969) Reference: PENLON. 1969. Anaesthetic Equipment - Longworth Scientific Instrument Company LTD. Abingdon, Berkshire, England. January 1969. Macintosh semi curved blade designed in a baby size, with an unfitted light bulb attached. Minor scratches and some slight hit marks over the piece surface caused by its previous use. It has the manufacturer name and the place where it was made along with the owner’s name engraved at the back of the blade. Engraved at the back of the blade near light bulb the owner details: R.C.H. / O.P.T. Stamped at the back blade base into metal the manufacturer's name and place: Longworth / MADE IN ENGLAND Stamped on light bulb base serrated surface, HEINE XHL / #059 2,5v paediatric blades, royal children's hospital, macintosh, light bulb, longworth, blade, laryngoscope -
Geoffrey Kaye Museum of Anaesthetic History
Laryngoscope, Shipway, c 1920
Shipway’s metallic medium size laryngoscope with bulbous curved handle. The section connecting the handle to the straight blade has a screw. Lateral orifice to attached light bulb connection which is not present on this item. The surface is very rusty and quite battered, presence of oxidation on its surface and discoloration of the metal. Has an inscription about the manufacturer.Stamped on its handle, MAYER & Co. LONDONshipway laryngoscope, laryngoscope, metal, mayer & co. london -
Geoffrey Kaye Museum of Anaesthetic History
Mask, Schimmelbusch, c. 1930s
Curt Theodor Schimmelbusch (November 16, 1860 – August 2, 1895) was a German physician and pathologist who invented the Schimmelbusch mask, for the safe delivery of anaesthetics to surgical patients. In 1890, Schimmelbusch invented a mask for the delivery of anaesthetics to surgical patients. It was primarily designed for ether anaesthesia, but he also proposed its use for chloroform anaesthesia. Schimmelbusch designed a metal mask, over which a gauze could be stretched and secured. The mask was placed over the patient's mouth and nose, and anaesthetic was applied to the gauze, allowing the patient to inhale the anaesthetic as they breathed normally. Around the edge of the mask, a trough collected the residual anaesthetic, rather than allowing it to drip onto the patient's face.Oval shaped metal mask with a collapsible cross-shaped dome, hinged clamp and flat handleStamped into underside of handle: ELLIOTT SYDNEYschimmelbusch, mask, open method, chloroform, ether, german, physician, pathologist -
Geoffrey Kaye Museum of Anaesthetic History
Slide
Colour slide mounted in white slide case. Image depicts modified Clover Inhaler with glass chamber, cloth rebreather bag and metal facemask against a green background.Handwritten in pencil: EMBLEY'S / 9448 -
Geoffrey Kaye Museum of Anaesthetic History
Slide
Colour slide mounted in white cardboard slide case. Image depicts modified Clover Inhaler with glass chamber, cloth rebreather bag and metal facemask. Handwritten in pencil: EMBLEY'S / 9448clover, joseph, inhaler, ether, chloroform -
Geoffrey Kaye Museum of Anaesthetic History
Inhaler, Probyn Williams (sectioned), c. 1900
Dr Geoffrey Kaye was a clinical anaesthetist at a time when very few full time anaesthetists existed. He was passionate about the training of future anaesthetists and would often section anaesthetic equipment to reveal its inner workings and show those to students. This Probyn Williams Inhaler is one apparatus which has been sectioned and the various elements of the inhaler have been painted to highlight the differences in function.Oval shaped metal inhaler with attached metal facemask. The inhaler has been sectioned to reveal its inner workings and the ether chamber has been painted black while the air-channel has been painted red. The manufacturer's logo, stamped into the inhaler, has been sectioned as well, leaving only half the information available.Engraved on dome side of inhaler: PROBYN WILLIAMS / G.K. sect. 1939 •Stamped into dome side of inhaler MAYER & / LON -
Geoffrey Kaye Museum of Anaesthetic History
Inhaler, Probyn Williams, c. 1900
In 1896 Robert James Probyn-Williams was appointed first honorary anaesthetist to the London Hospital and joined a select band of fulltime anaesthetists (26) in Great Britain. The Probyn Williams inhaler was a further modification of the Clover inhaler with narrow airways and rebreathing. The metal inhaler is ovoid shaped. The rotating gauge has a series of numbers engraved onto the inhaler for measurement. There is an elbow joint leading to a connector for attaching a re-breather bag, and at the other end is tap-style mechanism. There is a small glass bulb encased in a metal housing. The facemask is completely made of metal as well.Stamped into handle of tap: COEXTER & SONjoseph clover, frederick hewitt, robert probyn williams -
Geoffrey Kaye Museum of Anaesthetic History
Inhaler, Probyn Williams, c. 1900
In 1896 Robert James Probyn-Williams was appointed first honorary anaesthetist to the London Hospital and joined a select band of fulltime anaesthetists (26) in Great Britain. The Probyn Williams inhaler was a further modification of the Clover inhaler with narrow airways and rebreathing.Ovoid shaped metal ether inhaler device with a dark brown leather fask mask attached.Moulded into inhaler: MAYER & MELTZER / LONDON -
Geoffrey Kaye Museum of Anaesthetic History
Equipment - Case, c. 1903
Black round topped box with brass hooks at front and brass hinges at rear. There is a black fabric handle on the top (broken). Inside the box is black padding with the manufacturer's logo printed in gold leaf. There is a square section in the base of the box, usually for a glass bottle but which is holding a metal pourer. The rest of the kit is missing.Printed in gold leaf on inside lid of box: MAYER & MELTZER / LONDON / MELBOURNE & CAPE TOWN Stamped on underside of metal pourer: BARTH & CO / LONDON Handwritten on inside of lifting linen-covered paper: [indecipherable] d as described on Pawn-Ticket / January 1903 / Jacket / Boots [cont...]mayer & meltzer, barth & co -
Geoffrey Kaye Museum of Anaesthetic History
Accessory - Facemask
Pear shaped metal mask for attaching to Probyn Williams inhaler. The edge of the facemask is surrounded by a black leather cushion, with a tube on the top. The facemask is metal with a thumb action lever on connector.anaesthesia, inhalational, probyn williams, facemask -
Geoffrey Kaye Museum of Anaesthetic History
Equipment - Inhaler, Collison, c 1932
This device was designed by W E Collison for self administration of oxygen therapy, particularly in the home. By his own description "It presents none of the tiresome and irksome features associated with medical apparatus and is readily understood by patients." Registration number: 772839 and 785517 Patent number: 415437Metal tubing designed to attach to an oxygen cylinder which leads to a number of gauges and continues on to a metal head which holds two glass bulbs. Glass bulb on left is amber in colour and the glass bulb on the right is clear.Both bulbs have residue on the inside. Between the bulbs is a connecter that leads to red rubber tubing that is fluted toward the end.collison, oxygen therapy, inhaler -
Geoffrey Kaye Museum of Anaesthetic History
Equipment - Vaporiser, Penthrane, c. 1982
This vaporiser has a main cylindrical body with a step up to the dial plate with a small red latch to lock dial in to place.On the front of the body sits a square gauge to indicate the level FULL along with a long rectangular shape.There is an Inlet and outlet valve that sits behind the metal dial.There is a manufacturers plate sitting on top of the dial and the inlet/outlet valve. Inscribed on top plate: KEEP UPRIGHT/ PENTEC 2/ WHEN CHARGED •Inscribed on inlet & oulet valve plate: PENTEC 2/ SERIAL NO 252939/ PATENTS PENDING •MADE IN / ENGLAND BY/ CYPRANE LTD / KEIGHLEY •Metal dial has inscribed: OFF/.2 .5 1 1.5 2 Max •Inscribed on front plate in green writing: USE ONLY/ PENTHRANE/ (METHOXYFLURANE)penthrane, vaporizer, anaesthesia, anaesthetic machine -
Geoffrey Kaye Museum of Anaesthetic History
Instrument - Scarificator
Scarifiers were traditionally used for blood letting, and in folk medicine for the practice of cupping. Spring loaded knives cut the skin, then a warmed metal or glass cup is placed over the cuts. As the air inside the cup cools, it creates a vacuum drawing out the "bad" blood. The process is also related to the ancient medical theory of "humors". This theory dates back to the Hippocratic tradition and persisted through to the mid-19th Century. According to this theory, the body had four "humors", "airs" or "elements" which neeed to be kept in balance. Any imbalance could cause illness and this was often explained in terms of excess fluids. One prescribed treatment was to remove the excess blood which would restore the balance.Square, solid brass object with lever to release blades underneath.Etched on side: Mundy / Londonmetal, blades, bloodletting -
Geoffrey Kaye Museum of Anaesthetic History
Mask, Spectacle frame, c. 1930
The use of a catheter for oxygen therapy was introduced by Arbuthnot Lane in 1907. However, its true value can be seen in its use during WWI. Masks were cumbersome and uncomfortable for the wounded and nasal delivery of oxygen was received more easily. The Tudor Edwards' Spectacle-frame was manufactured in London during the 1930s. Dr Penn recorded that it was an inefficient means of oxygen therapy because of the smallness of the nasal tubes.Metal mask resembling spectacles with round frames and rounded ends of the arms to secure around the ear. There is a tube coming from each round eye frame to end in a curve that sits in the nostril. The other end of this tube has a rubber tube attached which meets in the middle via a metal connector.oxygen therapy, intra-nasal -
Geoffrey Kaye Museum of Anaesthetic History
Equipment - Mask
One of a range of metal face masks designed to have a cover which helps protect the patient's face.Wire frame mask designed to cover mouth and nose. There is a metal hook on the left hand side protuding from the base of the mask and wire mesh raised from the base with a circle in the middle.facemask, anaesthesia, ramsay surgical -
Geoffrey Kaye Museum of Anaesthetic History
Equipment - Sphygmograph, c. 1881 - 1901
They sphygmograph was devised as an improved device to measure blood pressure, and was a marked improvement on the first machine of its type. The sphygmomanometer was considered cumbersome and the Dudgeon sphygmograph was smaller, and once placed into its box, could be carried in a pocket. The Dudgeon sphygmograph was introduced in 1881. It was strapped tot he wrist with a metal strip that moved a stylus. This transmitted a record of the pulse onto smoked paper, creating a record of blood pressure.The sphygmograph is housed in a purple-lined, leather bound case with a metal hinge and clasp located halfway up the case. It is constructed from chrome and comprises several moving parts including wires, knobs and handles. A black fabric strap with a metal attachment is also present, used to attach to the patient's wrist.blood pressure, dudgeon, pocket-sized, portable -
Geoffrey Kaye Museum of Anaesthetic History
Resuscitator, 1962
The Porton resuscitator was devised in 1951 at the British Chemical Defence Experimental Establishment in Porton, Sailsbury, as a bellows-valve-mask resuscitator. Extensive testing was undertaken over eight years, with the device being successfully used for air transport of polio patients, for emergency resuscitation in hospital wards, and by hospital orderlies.Black rubber mask attached to a black concentina bag with a round metal filter at the end. Sits in its original wooden box with perspex lid. Instructions of use displayed on each side of the box. [white print on black rubber concertina bellows] PR 504 / P.B.C. 22 / - SEPT 1962resuscitator, porton -
Geoffrey Kaye Museum of Anaesthetic History
Functional object - Guedel's Airway
Oral airways, such as the Guedel, make it easier for patients to be ventilated with manual resuscitators, such as the Porton and the Ambu bag. They depress the tongue and prevent it from falling to the back of the throat where it would obstruct the airway.Black rubber curved tube with metal insert at baseHallmarked on metal: [BRITISHMADE / 3]guedel, -
Geoffrey Kaye Museum of Anaesthetic History
Photograph - Photograph, Geoffrey Kaye
Photograph has been taken in Geoffrey Kaye's later years, approximately late 1970s or early to mid 1980s.Large colour photograph of an elderly Dr Geoffrey Kaye wearing a white dustcoat and working on his lathe at his Cromwell Road, South Yarra home.geoffrey kaye, metal lathe, workshop -
Geoffrey Kaye Museum of Anaesthetic History
Photograph
Black and white photograph of a demonstration of a dental procedure on a patient who has received anaesthsia. Dr Geoffrey Kaye, wearing a white gown, is holding a dental suction hose and metal medical tray under the patient's mouth, who is leaning over the tray. An anaesthetist is holding an inhaler over the patient's nose. The background of the photo has been covered with black ink so that only Dr Kaye, the patient, and anaesthetist are visible.•Printed text in black ink on paper label glued under photo: Management of Vomiting. •Handwritten with blue ink on reverse: Photo. 8. / (Frame 29).anaesthesia, anaesthetist, geoffrey kaye, dental procedure, patient -
Geoffrey Kaye Museum of Anaesthetic History
Photograph
Black and white photograph of a drawing of anaesthetic equipment, a flowmeter and an ether vaporiser. On the right is the ether vaporiser inside a glass cylinder, with a control tap on top of it. It is attached to a metal cylinder which houses the flowmeter which is measuring the Oxygen and Nitrous Oxide. There is a round Oxygen control and a Nitrous Oxide control attached underneath the metal cylinder, as well as an Oxygen Bypass and a Nitrous Oxide Bypass. The diagram has each part of the apparatus named with an arrow pointing to the parts.ether vaporiser, anaesthetic equipment, flowmeter, nitrous oxide, oxygen -
Geoffrey Kaye Museum of Anaesthetic History
Photograph
Black and white photograph of a drawing of a portable drawover apparatus. There are two vaporisers with metal valves, one made of glass, connected to the ends of two corrugated tubes which are connected to a face mask at the other ends. A small rebreathing bag is connected to the underside of one of the vaporisers.Handwritten in black ink on surface of photograph the letters A - H, J, labelling each part of the apparatus.drawover apparatus, vaporiser, anaesthetic apparatus