Showing 7 items
matching insufflator
-
J. Ward Museum Complex
Functional object - Vaginal Insufflator for Silver Picrate, 1940's
The medical instrument is used for the treatment of Trichomonas Vaginitis. Insufflation has been a medical practice since the early nineteenth century, the earliest mention of it appearing in 1823. There are descriptions of its therapeutic and diagnostic purposes in connection with almost every cavity of the body. Despite being used widely across many Victorian health institutions, insufflation has not been regarded as a dangerous procedure.The object is significant because it is representative of medical treatments used to cure sexually transmitted diseases in Aradale Mental Hospital in the 1940's. Black leatherette covered wooden box with a metal latch on the front and 2 hinges at the rear. "Wyeth Vaginal insufflator for silver picrate" printed on inside of lid. Blue, painted wood, custom made interior. Contains: Four canisters of Silver Pictrate [Sealed] One canister of Silver Pictrate [attached to Insufflator] One canister of Silver Pictrate [Open but covered with a plastic top] One Vaginal Insufflator (Holmspray) Each bottle has a white paper label with blue banners at the top and bottom and blue text which reads in part reads "5 GMS Wyeth's compound silver picrate 1% powder" A receipt of sale dated 18 February 1944 is included in the box. Manufactured by John Wyeth & Bros Inc, Sydney, Australiamedical history, silver pictrate, trichomonas vaginitis, ararat mental hospital -
Ballarat Base Hospital Trained Nurses League
Insufflator
-
Royal Australian and New Zealand College of Obstetricians & Gynaecologists (RANZCOG)
Tubal insufflator associated with Dr Lorna Lloyd-Green, c1919
"Potential blockage in the Fallopian tubes was assessed using this apparatus. It was developed by American gynaecologist Isidor Clinton Rubin (1883-1958). It blows carbon dioxide, via a cannula, into the uterus. The ease with which gas escaped through the Fallopian tubes was reflected by pressure changes on an instrument called a manometer. Blockage of the tubes is often due to previous infection or surgery. It is a common cause of infertility. Rubin’s test formed a standard part of infertility investigations for many years. It was gradually replaced by an X-ray technique involving radio-opaque ‘dye’ injected into the uterus." Source: Science Museum Group. Rubin’s apparatus for uterotubal insufflation, New York, United States, 1928. A639503Science Museum Group Collection Online. Accessed 12 June 2024. https://collection.sciencemuseumgroup.org.uk/objects/co96774/rubins-apparatus-for-uterotubal-insufflation-new-york-united-states-1928-tubal-insufflator. Model may be dated c1919 or 1920s or 1930s. 1919 was the year Isidor Clinton Rubin (1883-1958) introduced the apparatus. Instrumant has a label with Cyrus Jones monogram " Donated by Dr Lorna Lloyd Green, 1986/ Rubin's Insufflator/ NB "sparklet holder separate" missing?Rubin's tubal insufflator apparatus, large cylidrical glass canister inside a portable carry box with two doors with three glass nozzels at top with long rubber tubing attached on each. One surigical steel introducer, one glass introducer attached. A blood pressure manometer is fixed on the inside door. infertility -
Royal Australian and New Zealand College of Obstetricians & Gynaecologists (RANZCOG)
Rubin's tubal insufflator apparatus associated with St Vincent's Hospital, c1919
"Potential blockage in the Fallopian tubes was assessed using this apparatus. It was developed by American gynaecologist Isidor Clinton Rubin (1883-1958). It blows carbon dioxide, via a cannula, into the uterus. The ease with which gas escaped through the Fallopian tubes was reflected by pressure changes on an instrument called a manometer. Blockage of the tubes is often due to previous infection or surgery. It is a common cause of infertility. Rubin’s test formed a standard part of infertility investigations for many years. It was gradually replaced by an X-ray technique involving radio-opaque ‘dye’ injected into the uterus." Source: Science Museum Group. Rubin’s apparatus for uterotubal insufflation, New York, United States, 1928. A639503Science Museum Group Collection Online. Accessed 12 June 2024. https://collection.sciencemuseumgroup.org.uk/objects/co96774/rubins-apparatus-for-uterotubal-insufflation-new-york-united-states-1928-tubal-insufflator. There is no manometer to monitor gas pressure on this model so it is either incomplete or a manometer was not available in this possibly early model. This device may be dated c1919, 1920s, or 1930s. 1919 was the year Isidor Clinton Rubin (1883-1958) introduced this apparatus. Rubin's tubal insufflator apparatus. Consists of a large cylindrical glass canister, with three glass nozzles at top with long rubber tubing attached to each. The device is inside a portable plywood box with two door. One surgical steel introducer, and one glass introducer, are also attached to the device. -
Ballarat Base Hospital Trained Nurses League
Sulphonamide Insufflator
Boxedsulphonamide, insufflator -
Royal Australian and New Zealand College of Obstetricians & Gynaecologists (RANZCOG)
Insufflator associated with midwife Mary Howlett, c. 1866 - 1920, Becton Dickson & Co
This appliance can used in two different ways: externally to spray antiseptic mist on to the skin or internally on the back of the throat. Insufflator is the clinical term for spraying. This was used by a midwife in the care of mother and newborn babies. (Becton Dickson)Mary Howlett (1840-1922) began practising as a country midwife in 1866 in the western district of Victoria. She qualified as a 'ladies monthly nurse' in 1887 and continued to practise as a nurse and midwife until 1920.She began her six months training at the Melbourne Lying-In Hospital. She was known by many as 'Auntie', and her career spanned more than 50 years. Mrs Howlett's midwifery box and contents were given to Dr Frank Forster, and he donated them to the museum collection in 1993.White metal applicator, probably made from nickel plate. Consists of three sections - application cup (.1), watch spring attached to a piston and flange (.2), and a section of metal connection (.3). Applicator was originally attached to a glass tube mounted on black vulcanite by metal connections of various sizes. Inscribed 'BECTON DICKSON & CO/PAT. DEC. 06", "RUTHERFORD N.J."midwifery, infant care -
Ballarat Base Hospital Trained Nurses League
Insufflators x 2