Showing 74 items
matching inhaler
-
Alfred Hospital Nurses League - Nursing Archive
Equipment - Inhaler, Dr Nelson's improved inhaler, [ca1900's]
Inhalation therapy has been used for over 2000 years, but it was from the early 19th century that different types of inhalers were developed. In 1865, Dr Nelson developed the improved Nelson inhaler. It is still manufactured today with very few modifications. The efficiency of the improved Nelson's inhaler is demonstrated by the ongoing use of the item since 1865. This simple inhaler is suitable for use in homes and hospitals. This white china inhaler has an air inlet spout and an opening at the top to add hot fluids, it holds 1 litre, and drugs to the inhaler. Once added, a cork with a glass mouth piece is placed in the neck of the inhaler. For this item plastic tubing has been used as the mouth piece.On front of body inscribed, 'Dr Nelson's improved inhaler': Directions for use. Remove mouth piece, half fill inhaler with boiling water. Replace mouth piece and apply lips to it, breathe freely in and out as in ordinary full respiration.steam inhaler, dr nelson's inhaler, medical apparatus -
South West Healthcare
Instrument - Inhaler, 1860-2000
Invented by Dr. Nelson in the mid 1860's, for the treatment of chest infections and inhalation issues.Ceramic inhaler with spout."Dr. NELSON'S / IMPROVED / INHALER"inhaler, inhalation, dr nelson, chest infection -
Geoffrey Kaye Museum of Anaesthetic History
Equipment - Inhaler, Hewitt, George Barth & Co. Ltd, c. 1895
Sir Frederic W. Hewitt (1857-1916), an accomplished and well respected English anesthesiologist, was an expert in the function and use of the Clover Ether Inhaler. In 1901, Hewitt described his modification of the Clover Inhaler. Often referred to as the Hewitt Wide-Bore Inhaler, Dr. Hewitt introduced changes in order to make it easier to breathe through the device and improve the ventilation of oxygen and carbon dioxide. In 1901, Hewitt was recruited to anesthetize King Edward VII for emergency abdominal surgery. This was just a day or so before the new King was to be coronated. He recovered well, and Hewitt became the first anesthesiologist ever to be knighted. (Source: Wood Library Museum)Tall black round topped box with brass hooks at the sides and brass hinges at rear. There is a brown fabric handle on the top. The box has red padding inside the lid and red lining inside the base and sides. There is a round section in the base of the box for holding the round clear glass bottle for ether. There is also a ellipse-shaped metal inhaler on small metal base with a thin metal handle and pipe with bakelite plug attached via a small metal chain. A brown mask is made of brown leather and celluloid which is connected to the inhaler. There is a metal ether measure for pouring the ether.On notecard in box: (B) HEWITT'S INHALER 1895, MADE BY GEO. BARTH & CO LTD., ADVERTISED AS THE SOLE MAKERS OF THE INHALER AND RECOGNISED BY HEWITT IN HIS TEXT BOOK - ANAESTHETICS AND THEIR ADMINISTRATION - AS THE MAKER OF HIS INHALER. / GIVEN BY DR. E.S. HOLLOWAY IN 1951, WHO ACQUIRED MUCH OF HOWARD JONES' EQUIPMENT AFTER THE LATTER'S DEATH. Stamped on underside of glass bottle in a circle: WUBW [illegible] Blue sticker on inhaler: O.2.13. Printed on inhaler under handle: Geo Barth [illegible] / SOL [illegible] Printed on body of inhaler: Full Printed on body of inhaler: 1/2 Printed on inside of leather mask: F35hewitt, sir frederic, jones, howard, inhaler, geo. barth & co. ltd., ether -
The Royal Children's Hospital Archives
Functional object, Dr Nelson's Improved Inhaler
Ceramic jug designed for inhaling fumes, for medical purposes.DR. NELSON'S IMPROVED INHALER. DIRECTIONS FOR USE: REMOVE MOUTHPIECE, HALF FILL INHALER WITH WATER REPLACE MOUTHPIECE & APPLY LIPS TO IT. BREATHE FREELY IN & OUT AS IN ORDINARY RESPIRATION. -
Geoffrey Kaye Museum of Anaesthetic History
De Ford Somniform Inhaler, E. De Trey & Sons Philadelphia, Pennsylvania, USA
The De Ford Inhaler was introduced in 1913 and was designed to allow anaesthesia to continue through the nose while dental surgery was happening.This inhaler is composed of metal and rubber. The oral mask and rubber covered nasal mask are connected to a curved rubber covered support that was placed on the patient's forehead to hold the inhaler in place. The gas was administered via a long tube; the terminus designed to allow for the placement of a vial containing the anaesthetic drug and a rebreather bag mount. Inscribed on the back of the mouth inhaler: 'Dr De Ford's Universal Inhaler for Somniform Nitrous Oxide etc. E. De Trey & Sons Phila. PA U.S. Pat. Pending.'anesthesia, dentistry, somniform, surgery, medical instrument, de ford, 1913, e de trey and sons, vial, rebreathr bag mount, inhaler -
Geoffrey Kaye Museum of Anaesthetic History
Inhaler, Probyn Williams, Mayer & Meltzer, c. 1900
In 1896 Robert James Probyn-Williams was appointed first honorary anaesthetist to the London Hospital and joined a select band of fulltime anaesthetists (26) in Great Britain. The Probyn Williams inhaler was a further modification of the Clover inhaler with narrow airways and rebreathing.Ovoid shaped metal ether inhaler device with a dark brown leather fask mask attached.Moulded into inhaler: MAYER & MELTZER / LONDON -
Geoffrey Kaye Museum of Anaesthetic History
Inhaler, Probyn Williams (sectioned), Mayer & Co. London, c. 1900
Dr Geoffrey Kaye was a clinical anaesthetist at a time when very few full time anaesthetists existed. He was passionate about the training of future anaesthetists and would often section anaesthetic equipment to reveal its inner workings and show those to students. This Probyn Williams Inhaler is one apparatus which has been sectioned and the various elements of the inhaler have been painted to highlight the differences in function.Oval shaped metal inhaler with attached metal facemask. The inhaler has been sectioned to reveal its inner workings and the ether chamber has been painted black while the air-channel has been painted red. The manufacturer's logo, stamped into the inhaler, has been sectioned as well, leaving only half the information available.Engraved on dome side of inhaler: PROBYN WILLIAMS / G.K. sect. 1939 •Stamped into dome side of inhaler MAYER & / LON -
Geoffrey Kaye Museum of Anaesthetic History
Photograph
The Bruck Inhaler is a modification of the Clover Inhaler, designed by Lambert Bruck.Colour photograph of a Bruck inhaler lying on its side on a wooden table. The metal inhaler is oval shaped with one half made of glass, and also has a vertical crosspiece. Lying next to the inhaler is a face mask and a filler for measuring ether.anaesthetic equipment, bruck inhaler, ludwig bruck, inhaler, clover inhaler -
Geoffrey Kaye Museum of Anaesthetic History
Inhaler, Bruck
The Bruck Inhaler is a modification of the Clover Inhaler, designed by Lambert Bruck. Bruck added a glass dome which enabled the level of ether to be monitored during administration. This was a revolutionary change as it removed guess work from the process.The inhaler is oval shaped with two halves. One half should be made of glass [missing] to allow observation of the ether level. A vertical cross tube, 22mm in diameter passes between the face-piece and the bag [broken]. There is a stopcock for admission of oxygen or nitrous oxide opposite the bag attachment. There is a central tube, 28mm in diameter, with controllable ports on either side.The Bruck Inhaler is a modification of the Clover Inhaler, designed by Ludwig Bruck. Bruck added a glass dome which enabled the level of ether to be monitored during administration. This was a revolutionary change as it removed guess work from the process.joseph clover, lambert bruck, inhaler, rebreather, nitrous oxide, oxygen, probyn williams, hewitt -
Geoffrey Kaye Museum of Anaesthetic History
Photograph
The Ormsby inhaler was modified by Carter Braine in 1898.Colour photograph of a Carter Braine modification of the Ormsby inhaler, sitting on a wooden table. The mask inhaler has a black rubber tubing around the mouthpiece, a metal cap and a wire net containing a natural sponge.anaesthetic equipment, carter braine, ormsby inhaler, inhaler -
Geoffrey Kaye Museum of Anaesthetic History
Inhaler, Clover (sectioned)
Dr. Joseph Clover (1825-1882), an English physician, first described his Portable Regulating Ether Inhaler on Jan. 20, 1877. Clover was an especially sought after anesthesiologist and early pioneer in the specialty. This was the best-known of many inhalers that Clover designed. The dome-shaped reservoir was turned to points on a control dial to gradually increase or decrease the percentage of the air that passed over the ether. Several inventors based new inhalers on this, while the original continued to be manufactured as late as the beginning of WWII. Dr Geoffrey Kaye sectioned equipment, enabling medical students to see the inner workings and gain insight into the engineering of the equipment.Cross section of Clover's inhaler attached to a circular metal base.Handwritten on white sticker at rear: P / 26 / B •White print on blue sticker: O.2.3. •Engraved on dome side of inhaler: G. Kaye sect. 1939.joseph clover, geoffrey kaye -
Geoffrey Kaye Museum of Anaesthetic History
Inhaler, Ether, Dewee, 1901
This is a simple metal mask with an ether chamber surmounting it. The patient breathes air down through the variable orifice over the surface of ether and in through the variable orifice over the surface of ether and in through the inspiratory valve. Exhalation was by means of the expiratory valve placed in the centre of the mask. All channels are extremely small and would offer considerable resistance to respiration.Metal inhaler with shaped rim edgeEngraved by hand into side of mask: DEWEE'S ETHER / INHALER.. 1901. Stamped into side of mask: J.E. LEECO / PATD. NOV. 12-1901 / 400ether, inhaler, ramsay, dewee, leeco -
South West Healthcare
Dr. Nelson's Inhaler, Dr.Nelson, Medical Equipment, 20th Century
Ceramic inhaler with spout"DR.NELSON'S/ IMPROVED /INHALER" -
Flagstaff Hill Maritime Museum and Village
Inhaler
Inhaler for chloroform, metal, chrome plated, with hinged frame, Schimmel Busch type. Small.flagstaff hill, warrnambool, shipwrecked-coast, flagstaff-hill, flagstaff-hill-maritime-museum, maritime-museum, shipwreck-coast, flagstaff-hill-maritime-village -
Flagstaff Hill Maritime Museum and Village
Inhaler
Inhaler for chloroform, metal, chrome plated, with hinged frame, Schimmel Busch type. Large.flagstaff hill, warrnambool, shipwrecked-coast, flagstaff-hill, flagstaff-hill-maritime-museum, maritime-museum, shipwreck-coast, flagstaff-hill-maritime-village -
Geoffrey Kaye Museum of Anaesthetic History
Equipment - Inhaler, Clover, Mayer & Meltzer
Dr. Joseph Clover (1825-1882), an English physician, first described his Portable Regulating Ether Inhaler on Jan. 20, 1877. Clover was an especially sought after anesthesiologist and early pioneer in the specialty. This was the best-known of many inhalers that Clover designed. The dome-shaped reservoir was turned to points on a control dial to gradually increase or decrease the percentage of the air that passed over the ether. Several inventors based new inhalers on this, while the original continued to be manufactured as late as the beginning of WWII. Dome shaped metal chamber with a red leather face mask attached at one end and a metal elbow joint at the other, including a bulb for a rebreather bag and a tap mechanism.Engraved on dome of chamber: Mayer & Meltzer / London / Clover's Inhaler •Stamped on flat base of chamber: 1 2 3 1 2 3joseph clover, portable, inhaler -
Geoffrey Kaye Museum of Anaesthetic History
Inhaler, Clover, Mayer & Meltzer, 1877
Dr. Joseph Clover (1825-1882), an English physician, first described his Portable Regulating Ether Inhaler on Jan. 20, 1877. Clover was an especially sought after anesthesiologist and early pioneer in the specialty. This was the best-known of many inhalers that Clover designed. The dome-shaped reservoir was turned to points on a control dial to gradually increase or decrease the percentage of the air that passed over the ether. Several inventors based new inhalers on this, while the original continued to be manufactured as late as the beginning of WWII. (Source: Wood Library Museum)Black round topped box with brass hooks at front and brass hinges at rear. There is a black fabric handle on the top. Inside the box is black padding with the manufacturer's logo printed in gold leaf. There is a square section in the base of the box for holding the square clear glass bottle for ether. There is also a dome-shaped metal inhaler with a "whistle tip" type connection to the mask. The mask is made of tan leather. There is also a metal ether measure for pouring the ether.Printed in gold leaf inside lid of box: MAYER & MELTZER [?] PORTLAND ST. / MAKERS •Engraved on side of inhaler: Mayer & Meltzer / London •Stamped on connector of inhaler: MAYER & MELTZER RN NO 212327 •Engraved on rear of inhaler: Clover's Inhaler •Printed in white on blue sticker: O.2.5A •Measurements have been stamped on the bottom of the inhaler. •Printed in black ink on mask: MADE IN ENGLAND •Stamped on metal connector inside mask: 6 •Printed in black ink on white manufacturer's label on glass bottle: ETHER PURUS '720 / H. Francis & Co., Melbourne.clover, joseph, mollison, crawford henry, george bankin, mccaul, kevin, royal women's hospital, coroner, freemason, surgeon, gynaecologist, obstetrician, mayer & meltzer, francis & co, melbourne, ether purus -
Kiewa Valley Historical Society
Medical - Portable Inhaler
The inhaler can be used in hospitals in the labour ward for the patient to absorb trichloroethylene. The inhaler can be mounted on the bracket which can be secured to the leg of a labour bed. The inhaler contains a wick which absorbs trichloroethylene and will function for several hours.This inhaler was used in the Tawonga District Hospital.Wooden box with corners strengthened with steel plate and lid on 2 hinges. Lid has 3 rectangular lengths of wood attached to enhance packing and a yellow piece of paper with red writing stapled on. Box contains 2 metal clamps, a light metal stand/bracket with screw and holder and a hard black plastic mask. In the other side: 2 sheets including Instructions, a small paper bag with spare washers, a light brown extendable hose with metal attachment at one end and a light brown oval rubber bladder with a hole at one end to fit over the hose. Light metal Inhaler - 3 cylinders of different diameters attached to a plate. Red markings / writing and plate incl. serial no. Yellow paper on lid explains "...packing box is supplied free with the Tecota mark 6 Inhaler..." Mask: Cyprene Ltd / Keighley /Made in England Instructions / for the preparation of / Tecota / Mark 6 / Trichloroethylene B.P. / Inhaler Bladder: A Cig Product / 4 litre / Made in England to Inhaler: Cyprane Ltd. / Max Min / Pat No 646680 / Patents Pending / Tecota Mark 6 / Charge with / Trichloroethylene B.P. / Cyprane Ltd. / Serial No. / Keighley / Yorks.medical. hospital. inhaler. trichloroethylene. childbirth.tawonga district hospital -
Geoffrey Kaye Museum of Anaesthetic History
Clover's modified ether inhaler, Coexeter, London, 1876
This is a modified version of the original Clover inhaler. Joseph Thomas Clover preferred this modified version over his later, portable regulating ether inhaler.This modified Clover's ether and chloroform inhaler is composed of metal and is cylindrical in shape. There is a gas distribution control key on the top and a metal hook enables the operator to hang the vaporiser from a strap around his/her neck. Stamped on top tap: COEXETER LONDONjoseph thomas clover, inhaler, ether, anaesthetic, portable, nitrous oxide, modified, gas, coexeter london, chloroform, rebreather bag, face mask -
Geoffrey Kaye Museum of Anaesthetic History
Inhaler, Snow (replica), 1950
John Snow was England's first full-time anaesthetist. He noted that the common mode of administration of ether was liable to lead to anoxia, and invented this inhaler to overcome this. Later, he turned to chloroform anaesthetics without a death. He administered chloroform to Queen Victoria for the birth of Prince Leopold, this largely being responsibe for overcoming objections to the use of analgesia in childbirth. This replica was made in 1950 and gifted to the museum by A Charles King Esquire.The complete object is in six parts and made up of a brass metal box with swing latches in the middle section for secure closing. The lid is in two parts with one half that comes off entirely. Inside the box is the circular inhaler, detachable tube and dark yellow/green fabric covered tube. The mask made of brass and chamois leather with an exporatory valve does not fit into the box. A brown fabric case has been made to store the inhaler in.Etched onto the detachable lid, This replica of the Snow's Ether Inhaler of 1847 was made by John Henry Hawkes of A. Charles King Ltd. August 1950.john snow, chloroform, ether, queen victoria, prince leopold, john henry hawkes, a. charles king -
Geoffrey Kaye Museum of Anaesthetic History
Inhaler, Bruck, 1908
The Bruck Inhaler is a modification of the Clover Inhaler, designed by Lambert Bruck. Bruck added a glass dome which enabled the level of ether to be monitored during administration. This was a revolutionary change as it removed guess work from the process.The Bruck Inhaler is a historically, aesthetically and scientifically significant piece. The basic design is based on the Clover Inhaler, but with a rounded bottom. The idea of a glass viewing window was possibly inspired by Wilson-Smith Inhaler. The Bruck Inhaler is historically significant as it is the first inhaler to be made with a completely clear lower glass section. This improved the usability for the ether administrator, and eliminated much of the guesswork associated with dosage and ether levels, which in turn improved the patient experience. This piece provides a strong local link to both anaesthetic and general medical practice at the turn of the century. The design is credited to Ludwig Bruck of Sydney, and was presumably manufactured in the same area. Bruck, as the attributed designer, holds much relevance to the significance of the object, as connected with him is much historical information about the social context of medical practice. Ludwig Bruck was a prominent figure in the medical industry. He started his medical career in Sydney as a Medical Transfer Agent, and later owned a shop at 16 Castlereagh Street, Sydney. This business is listed in the 1903 Register of Firms as a Medical Agent and Importer of Medical Instruments and Books. Bruck was vocal as a journalist and published analyses of medical statistics, as well as the well known Australasian Medical Dictionary and Handbook, which included the “List of Unregistered Medical Practitioners”. Ludwig Bruck was an immigrant. He was of German descent, which placed him in a precarious position within Sydney society during the turn of century. Bruck conducted several public conversations with prominent members of the Australian Natives Association through the Sunday News in regards to his disagreement of the employment of medical practitioners by the ANA specifically to corroborate their health insurance policies. He was also a stalwart supporter of the Australian arm of the British Medical Association, being the publisher of the first and subsequent editions of The Australian Medical Gazette. Bruck chose to end his life with a combination of poison and chloroform on 14 August 1915, after being accused of trading with the enemy during World War One. His suicide note stated his horror at leaving his business partner to deal with the tarring of his reputation as the reason for his decision. The Bruck Inhaler has aesthetic significance as it is a beautiful example of turn of the century surgical design and craftsmanship. Aseptic methods of surgery were well known by 1909, and the aesthetic design of the Bruck Inhaler conformed to these principles. The ability for the surgeon to unscrew, clean and sterilize each part of the Inhaler contributes to the streamlined design of the piece. The Buck Inhaler holds scientific significance. There is the capacity for further research to be undertaken on the object. Geoffrey Kaye often collected multiple examples of equipment, usually one for reverse engineering and another for teaching. There are currently two examples of the Bruck Inhaler in the collection, presenting an opportunity for further technical research on the object. The inhaler is oval shaped with one half made of glass to allow observation of the ether level. A vertical cross tube, 22mm in diameter passes between the face-piece and the bag [missing]. There is a stopcock for admission of oxygen or nitrous oxide opposite the bag attachment. There is a central tube, 28mm in diameter, with controllable ports on either side. There is also a tear-drop shaped fask mask.Hand engraved on side of base: L. Bruck / Sydneyclover, joseph, bruck, lambert, inhaler, rebreather, nitrous oxide, oxygen, williams, probyn -
Geoffrey Kaye Museum of Anaesthetic History
Inhaler, Ether, Small
Dr Thomas Small designed this ether anaesthesia and analgesia machine while he was an Honorary Medical Officer at the Royal Women's Hospital in Sydney during the 1930s. The inhaler is compact and portable. Initially, Small experimented with other agents for the relief of labour pain but was not happy with any of them. He also tried various agents on himself, including nitrous oxide/oxygen, chloroform and ethyl chloride. Finally he settled on ether via a Clover inhaler as the best analgesic. This inhaler is only described in use in Australia and New Zealand, although it was used for almost 40 years. Black leather box with leather handle, lockable latches on either side and drop down front case panel containing a metal ether inhaler and length of black corrugated rubber hose with one end attached to the inhaler and the other end open for attaching a mask. The metal inhaler drum is circular and attached to the floor of the case with a small tap/lever to one side and a mixing valve on the top near the hose connection. The lever has incised gradings of quarter increments from 0 to 1. The box is designed for the ether inhaler to be portable.ether, small, thomas, analgesia, obstetrics, anaesthesia, anaesthetic, royal women's, sydney, queen victoria, melbourne -
Geoffrey Kaye Museum of Anaesthetic History
Photograph
Colour photograph of an Ormbsy inhaler lying on a wooden table. The inhaler has a metal mouthpiece with rubber tubing around the edge, and a rubber bag inside a black netbag.anaesthetic equipment, ormsby inhaler, inhaler, portable -
Geoffrey Kaye Museum of Anaesthetic History
Inhaler, Clover, Mayer & Meltzer
Dr. Joseph Clover (1825-1882), an English physician, first described his Portable Regulating Ether Inhaler on Jan. 20, 1877. Clover was an especially sought after anesthesiologist and early pioneer in the specialty. This was the best-known of many inhalers that Clover designed. The dome-shaped reservoir was turned to points on a control dial to gradually increase or decrease the percentage of the air that passed over the ether. Several inventors based new inhalers on this, while the original continued to be manufactured as late as the beginning of WWII.Metal dome shaped chamber with an elbow joint for attaching a rebreather. A cotton rebreather bag is attached.Engraved on dome: Mayer & Meltzer / London / Clover's Inhalerjoseph clover, edward henry embley, closed administration, rebreather -
Geoffrey Kaye Museum of Anaesthetic History
Inhaler, Probyn Williams, Mayer & Meltzer, c. 1900
Hurley, Sir Thomas Ernest Victor (1888-1958) was gifted this Probyn Williams inhaler in 1914. After studying at Melbourne University, Victorian-born Hurley was a Medical Officer at the Royal Melbourne Hospital until he commenced private practice in Collins Street. He was appointed Captain Australian Army Medical Corps, AIF and served in Gallipoli with the 2nd Field Ambulance. He served in Enypt, London, and the Western Front during World War 1. He gained a Companion of the Order of St George and St Michael in 1917. Upon return to Melbourne he held positions such as surgeon to Victoria Police (1928-1956), elected to Council of the Victorian branch of the British Medical Association, member of the Charities Board of Victoria and foundation member of the Royal Australasian College of Surgeons and chaired the Flying Personnel Research Committee m a consulting surgeon at the Royal Melbourne Hospital. This apparatus is transitional between Clover's and Hewitt's having Clover's narrow "ways" and compact size, but using Hewitt's ether-control lever.Black round topped box with brass hooks [missing] at front and brass hinges at rear. The initials T.E.V.H. are printed in gold leaf on the front. There is a black fabric handle on the top. Inside the box is black padding with the manufacturer's logo printed in gold leaf. There is a square section in the base of the box for holding the square clear glass bottle for ether. The pear-shaped mask is made of metal. There is also a metal ether measure for pouring the ether. The metal inhaler is ovoid shaped. The rotating gauge has a series of numbers engraved onto the inhaler for measurement. There is an elbow joint attaching a re-breather bag, with a small amount of waxy paper remaining attached with a thin ribbon. There is a small glass bulb encased in a metal housing. Printed in gold leaf on front of box: T.E.V.H. •Printed in gold leaf on inside lid of box: MAYER & MELTZER / LONDON / MELBOURNE & CAPE TOWN •Engraved on side of inhaler: PRESENTED / TO / T.E.V. Hurley Esq.,M.D.M.S. / by / THE M.S.S. / 15.6.14. •Engraved on reverse side of inhaler: PROBYN WILLIAMS / ETHER INHALER •Moulded into connector on elbow joint: MAYER & MELTZER •Stamped into base of metal pourer: MAYER & MELTZER / LONDON •Blue sticker with white printed text on front of inhaler: O.2.21.hurley, thomas ernest victor, probyn williams, university of melbourne, world war 1, wwi, gallipoli, australian army medical corps, medical student society, mayer & meltzer, clover, joseph, hewitt, fredrick william -
Geoffrey Kaye Museum of Anaesthetic History
Inhaler, Probyn Williams, c. 1900
In 1896 Robert James Probyn-Williams was appointed first honorary anaesthetist to the London Hospital and joined a select band of fulltime anaesthetists (26) in Great Britain. The Probyn Williams inhaler was a further modification of the Clover inhaler with narrow airways and rebreathing. The metal inhaler is ovoid shaped. The rotating gauge has a series of numbers engraved onto the inhaler for measurement. There is an elbow joint leading to a connector for attaching a re-breather bag, and at the other end is tap-style mechanism. There is a small glass bulb encased in a metal housing. The facemask is completely made of metal as well.Stamped into handle of tap: COEXTER & SONjoseph clover, frederick hewitt, robert probyn williams -
Geoffrey Kaye Museum of Anaesthetic History
Inhaler, Clover, c. 1877
Dr. Joseph Clover (1825-1882), an English physician, first described his Portable Regulating Ether Inhaler on Jan. 20, 1877. Clover was an especially sought after anesthesiologist and early pioneer in the specialty. This was the best-known of many inhalers that Clover designed. The dome-shaped reservoir was turned to points on a control dial to gradually increase or decrease the percentage of the air that passed over the ether. Several inventors based new inhalers on this, while the original continued to be manufactured as late as the beginning of WWII.Metal domed chamber with a bulb attachment on an elbow joint for rebreather bag. There is also a connector for a facemask, but no facemask.White printing on blue sticker: O.2.2. •Engraved on dome: Clover's Inhaler / 1877.joseph clover, portable regulating ether inhaler -
Ballarat Base Hospital Trained Nurses League
Improved Inhaler
Improved InhalerCeramic JugMade in Englandimproved, inhaler, ballarat -
Geoffrey Kaye Museum of Anaesthetic History
Inhaler, Clover (modified), Allan & Hanbury
Dr. Joseph Clover (1825-1882), an English physician, first described his Portable Regulating Ether Inhaler on Jan. 20, 1877. Clover was an especially sought after anesthesiologist and early pioneer in the specialty. This was the best-known of many inhalers that Clover designed. The dome-shaped reservoir was turned to points on a control dial to gradually increase or decrease the percentage of the air that passed over the ether. Several inventors based new inhalers on this, while the original continued to be manufactured as late as the beginning of WWIIMetal based inhaler with glass dome lid. From the glass dome an elbow joint leads to a bulb for a rebreather bag [no bag]. There is a cork sealing an opening at the rear of the metal base and a blue sticker adhered.Printed in white on blue sticker: O.2.10 Manufacturer's logo moulded into metal insertjoseph clover, portable regulating ether inhaler -
Geoffrey Kaye Museum of Anaesthetic History
Inhaler, Hewitt's (modified), Coxeter
Sir Frederick William Hewitt (1857-1916) wrote one of the earliest comprehensive textbooks on anaesthesia, and designed several pieces of anaesthetic equipment. In 1901, he described his wide-bore ether inhaler, a modification of the Clover Ether Inhaler. Unlike the Clover, it can be refilled with ether while still in use, and the mask is screwed into place so that it "cannot be unexpectedly detached." This version is a modified Hewitt's Inhaler which has a narrower 'ways' than the original Hewitt's, and no water compartment. Additionally, one side of the bowl is made of glass which enabled the person administering anaesthesia to see the level remaining in the bowl. Bowl shaped inhaler with a glass bowl base and metal dome top with a connector which appears to be for a rebreather bag. There is a metal switch at the base of the glass bowl to alter or regulate the flow.Stamped into central tube: COXETER LONDON Stamped into side of metal dome: 6460hewitt, wide-bore, clover, ether, anaesthesia, anesthesiology, anaesthesiology